Thank you for purchasing the F3SJ-BP25-02TS Series Safety Light Curtain (hereinafter referred to as the "F3SJ-B-02TS"). This document is a brief description from wiring to pre-operation checklists / maintenance checklists of F3SJ-B-02TS. For details, download and read F3SJ-B-02TS operation manual and user's manual from Omron's website. https://industrial.omron.us/en/home Table of Contents 1.
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 4. Function Selection Flow Chart Required system configuration depends on functions to be used. Use the following flow chart to determine the system. Using Muting Function Basic System Muting System *1 *1 Muting Key Cap (F39-CN10) is necessary.
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 5.Wiring Examples For wiring examples of input/output circuit and other wiring examples than below, refer to F3SJ-B-02TS series user's manual. 5-1. EDM not used, auto reset mode, external test used, muting function not used, PNP output F39-JD A-L F39-JD A-D...
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 6. Mounting and Beam Alignment For brackets other than top/bottom brackets (F39-LJB1) and intermediate brackets (F39-LJB2) as well as external dimensions and mounting, refer to F3SJ-B-02TS series user's manual. 6-1. Mutual Interference Prevention ■...
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 6-5. Mounting and Beam Alignment Mounting brackets are not included in the product. You must purchase them separately. Step1 1. Loosen the intermediate mounting bracket bolts. Check position <Backside mounting> Hexagon socket head cap screw (M3 x 12) Loosen...
Page 10
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 3. Attach the top/bottom brackets to the case. <Backside mounting> Hexagon socket head cap screws (M3 x 6) Step1 (Recommended tightening torque: 0.54Nm) Tighten lightly Check Loosen position Anti-rotation hexagon socket head cap screw Tighten Step2...
Page 11
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 5. Align beams based on the indicators. Align the unit to the center of the angle where stable indicator (STB) turns ON Align the unit to the center Step1 of the angle where stable indicator (STB) turns ON Emitter Receiver...
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists 7. Pre-Operation Checklists / Maintenance Checklists After wiring, mounting and beam alignment are done, check the operation of the F3SJ-B-02TS. Pre-Operation Checklists After installation, the highest level administrator must use the following checklist to verify the operation, plac- ing a check mark in each of the boxes.
Page 13
Pre-Operation Checklist / Function Selection Wiring Mounting/Beam Alignment Maintenance Checklists Depending on the unit's model and settings of floating blanking function, detection capability may vary. Use a test rod with an appropriate diameter for inspection. The model name of test rod is as follows. Model name Diameter F39-TRD25...
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use.