Fluid Specifications - Danfoss MP1 Service Manual

Axial piston motors size 20/24
Hide thumbs Also See for MP1:
Table of Contents

Advertisement

Service Manual
MP1 Motor
Technical Specifications

Fluid Specifications

Features
Intermittent
Minimum
Viscosity
Recommended range
Maximum (cold start)
Minimum (cold start)
Recommended range
3
Temperature range
Maximum continuous
Maximum intermittent
Cleanliness per ISO 4406
1
Intermittent=Short term t <1 min per incident and not exceeding 2 % of duty cycle based load-life.
2
Cold start = Short term t < 3 min, p < 50 bar [725 psi], n < 1000 min
3
At the hottest point, normally case drain port.
10 |
©
Danfoss | November 2020
Units
1
2
mm
/sec. [SUS]
2
°C [°F]
-1
(rpm)
20/24
5 [42]
7 [49]
12 - 80 [66 - 370]
1600 [7500]
-40 [-40]
60 - 85 [140 - 185]
104 [220]
115 [240]
22/18/13 (as per ISO 4406)