Snorkel MHP15J Operator's Manual page 19

Engine powered gasoline battery electric
Hide thumbs Also See for MHP15J:
Table of Contents

Advertisement

RCD/ELCB AC outlet
RCD
Power Outlet
At Platform
Power Input
Connector
Figure 2.8 - RCD/ELCB AC Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at
the base and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form out -
let.
To re set the out let dis con nect the power tool lead
from the plat form box and re set the RCD at the
base.
If the prob lem per sists call a trained ser vice tech ni -
cian.
Flashing light
Figure 2.9 - Flashing Light
The flashing light alerts people that the MHP15J is
moving. The light flashes at about one flash per
second any time the MASTER KEY switch is on.
There is no ON/OFF switch for the flashing light, it
cannot be turned off while the MHP15J is running.
MHP15J – 11995A
2. Safety Devices
page 2 - 3

Advertisement

Table of Contents
loading

Table of Contents