Installation Manual; Notices For Installation; Installation Site Instructions; Installation Site Of Indoor Unit - Tadiran Telecom SMVH09A-2A1B1NA Service Manual

Table of Contents

Advertisement

Installation Manual

7. Installation Manual

7.1 Notices for Installation

Caution
1.The unit should be installed only by authorized service center according to local or government regulations and in compliance
with this manual.
2.Before installing, please contact with local authorized maintenance center. If the unit is not installed by the authorized service
center, the malfunction may not be solved due to incovenient contact between the user and the service personnel.
3.When removing the unit to the other place, please firstly contact with the local authorized service center.
4.Warning: Before obtaining access to terminals, all supply circuits must be disconnected.
5.For appliances with type Y attachment, the instructions shall contain the substance of the following. If the supply cord is
damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
6.The appliance must be positioned so that the plug is accessible.
7.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube.
8.The instructions shall state the substance of the following:This appliance is not intended for use by persons(including
children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

7.1.1 Installation Site Instructions

Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1.The place with strong heat sources,vapors,flammable or explosive gas,or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine,medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.

7.1.2 Installation Site of Indoor Unit

1. There should be noobstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be ableto withstand the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m above fioor.
7. Don't install the indoor unit right above the electric appliance.
8.Please try your best to keep way from fluorescent lamp.
7.1.3 Safety Precautions for Electric Appliances
1.A dedicated power supply circuit should be used in accordance with local electrical safety regulations.
2.Don't drag the power cord with excessive force.
3.The unit should be reliably earthed and connected to an exclusive earth device by the professionals.
4.The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload.
5.The minimum distance between the unit and combustive surface is 1.5m.
6.The appliance shall be installed in accordance with national wiring regulations.
7.An all-pole disconnection switch with a contact separation of at least 3mm in all poles should be connected in fixed wiring.
Note:
● Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected.
There should be reliable circuit in the diagram.
● Inadequate or incorrect electrical connections may cause electric shock or fire.
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents