Tadiran Telecom TGI-07H Technical Manual

Tgi series
Hide thumbs Also See for TGI-07H:

Advertisement

Technical Manual
Split System Air Conditioner
TGI -SERIES
TGI-07H
TGI-09H
TGI-12H
TGI-18H
March 2003 ver - B

Advertisement

Table of Contents
loading

Summary of Contents for Tadiran Telecom TGI-07H

  • Page 1 Technical Manual Split System Air Conditioner TGI -SERIES TGI-07H TGI-09H TGI-12H TGI-18H March 2003 ver - B...
  • Page 2: Table Of Contents

    Contents 1. PART NAMES AND FUNCTIONS........2. SPECIFICATION............... 3. OUTLINES AND DIMENSIONS..........4. WIRING DIAGRAM..............5. REFRIGERANT SYSTEM DIAGRAM ........13 6. PERFORMANCE DATA............17 7. SERVICE FLOW CHART............23 8. SPARE PARTS LIST ............... 26 9. CONTROL MODE ..............30 10.SENSOR PARAMETERS............
  • Page 3: Part Names And Functions

    1. PART NAMES AND FUNCTIONS TGI-07H TGI-09H TGI-12H Air intake grille INDOOR UNIT Air outlet Drain hose Remote controller unit Refrigerant tubes OUTDOOR UNIT Air outlet INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp HIGH HI POWER POWER POWER TIMER...
  • Page 4 1. PART NAMES AND FUNCTIONS TGI-07H TGI-09H TGI-12H REMOTE CONTROLLER Transmitter Sensor Fan speed selection button On/Off button 1 HOUR TIMER Temperature setting button Hi-power running Flap Mode selection button Sleep button Timer on/off button Set/cancel timer button A/C sensor button...
  • Page 5 1. PART NAMES AND FUNCTIONS INDOOR UNIT OUTDOOR UNIT...
  • Page 6 1. PART NAMES AND FUNCTIONS REMOTE CONTROLLER Transmitter Sensor T. SETTING AUTO On/Off button 1 HOUR TIMER Temperature setting button HOUR 1 HR ON / OFF TEMP. Mode selection button Hi-power running HIGH POWER Flap FLAP MODE Fan speed selection button Timer on/off button FAN SPEED Sleep button...
  • Page 7: Specification

    2. SPECIFICATION TGI-07H TGI-09H Model ~ 50Hz Power supply AC 220V ~ 50Hz AC 220V Heating Cooling Heating Cooling Units Function Capacity 2.30 Capacity Dehumidification Capacities Air flow Power outlet Running current 3.50 3.30 Power input A(KW) Auxiliary heater Electrical...
  • Page 8 2. SPECIFICATION TGI-12H TGI-18H Model ~ 50Hz Power supply AC 220V ~ 50Hz AC 220V Heating Heating Cooling Units Cooling Function Capacity Capacity Dehumidification Capacities Air flow Power outlet Running current 10.0 1220 1260 1850 2100 Power input A(KW) Auxiliary heater Electrical Data Power factor...
  • Page 9 TGI-07H TGI-09H TGI-12H 50.5 130.5 124.5...
  • Page 10 TGI-07H TGI-09H TGI-12H...
  • Page 11 TGI-18H...
  • Page 12 TGI-18H...
  • Page 13 TGI-07H TGI-09H TGI-12H INDOOR UNIT YLW/GRN YLW/GRN OUTDOOR UNIT...
  • Page 14 TGI-18H INDOOR UNIT OUTDOOR UNIT...
  • Page 15 TGI-07H , TGI-09H INDOOR UNIT OUTDOOR UNIT Rerigerant pipe 9.52 (With heat insulator) Service valve Heat exchanger 4-way valve Flare connection Indoor coil Heat exchanger sensor Indoor temperature MUFFLER sensor Compressor Capillary tube 1.42 X 700 Flare connection Strainer Dryer...
  • Page 16 TGI-18H OUTDOOR UNIT INDOOR UNIT 4-way valve Heat exchanger Rerigerant pipe 12.7) Heat exchanger (With heat insulator) Muffler Service valve Indoor coil Flare d connection sensor Indoor temperature Accumulator sensor Capillary tube 1.8 X 460 Compressor Flare d connection Strainer Rerigerant pipe Service valve Capillary tube...
  • Page 17 MAX. REFRIGERANT PIPING LENGTH & HEIGHT DIFFERENCE Piping size O.D : [mm] Refrigerant piping Max. Height Models Max. length A [m] difference B [m] Liquid TGI-07H 6.35 9.52 TGI-09H 6.35 9.52 TGI-12H 6.35 12.7 TGI-18H 6.35 12.7 Indoor unit Refrigerant piping Max.
  • Page 18: Evacuation Procedures

    EVACUATION PROCEDURES Stop valve Liquid pipe Hexagonal Close wrench Gage Gas pipe manifold Open valve Caps Connection Stop valve pipe Hexagonal Stop Service port wrench valve Vacuum pump...
  • Page 19 COOLING CAPACITY Outdoor intake air DB C Indoor intake MODEL Air (WB C) TGI-07H 2522 2336 2173 1963 1778 1037 1508 1182 2701 2559 2376 2142 1960 1061 1752 1137 TGI-09H 2783 2659 2593 2351 1002 2166 1077 1943 1164...
  • Page 20 HEATING CAPACITY Outdoor intake air WB C Indoor intake MODEL Air (DB C) TGI-07H 1702 2061 2471 2866 3199 3492 1015 TGI-09H 1587 2044 2361 2840 3153 1042 3428 1103 1560 1950 2265 2685 1010 3062 1117 3032 1126 2256...
  • Page 21: Performance Data

    6. PERFORMANCE DATA TGI COOLING CAPCITY CURVE CAPACITY BTU TGI 9 CAPACITY BTU TGI 12 18000 CAPACITY BTU TGI 18 16000 16745 16384.6 15963 15361.2 14000 14779.8 12858.8 13066.2 12000 12736.4 12066.6 11226.8 10000 10747.4 9809 9462.2 9040.6 8000 8816.2 7993.4 7364.4 6000...
  • Page 22 6. PERFORMANCE DATA TGI 9 BTU/H TGI HEATING CAPACITY BTU\H TGI 12 BTU/H 30000 TGI 18 BTU/H 26788.6 25000 23650.4 20590.4 20000 17816 15867.8 15000 12678.6 12607.2 12260.4 9829.4 13236.2 8445.6 10000 11655.2 7082.2 10720.2 9656 8027.4 5000 6949.6 5395.8 OUTDOOR TEMPERATURE WB...
  • Page 23 6. PERFORMANCE DATA TGI COOLING WATT CAPACITY AMBIENT TEMPERATURE COIL MODEL INLET 2522 2336 2173 1963 1778 1508 1182 2701 2559 2376 2142 1960 1752 1137 TGI 09 2783 2659 2593 2351 1002 2166 1943 1164 2893 2824 2800 2587 1029 2341 2137...
  • Page 24 6. PERFORMANCE DATA TGI HEATING WATT CAPACITY OUTDOOR WB TEMPERATURE MODEL 1702 2061 2471 2866 3199 3492 1015 TGI 9 WATT 1587 2044 2361 2840 3153 1042 3428 1103 1560 1950 2265 2685 1010 3062 1117 3032 1126 2256 2866 1043 3242 1134...
  • Page 25 Switch on the power supply Does it receive the Does the LED Start up self-diagnosis function signal of remote controller ? display Normally? Check the trouble Is the fuse blown ? Is remote controller Remote controller in good condition ? trouble or replace the battery Is the wires...
  • Page 26 Running light flickers Timer and power light flicker indoor heat exchanger Indoor heat exchanger is Is overload Freezed Is indoor heat exchanger Indoor coil sensor Is indoor heat Indoor coil sensor very hot ? trouble exchanger Freezed ? Is compressor Is compressor Normal protection Normal protection...
  • Page 27 High power light flickers indoor fan motor trouble Timer and running and power light flicker over current trouble High power or running light flickers EEPROM trouble...
  • Page 28: Spare Parts List

    8. SPARE PART LIST INDOOR UNIT Key No. Part No. Description TGI-07 TGI-09 TGI-12 529-0-0000-062-0A-0 Steppor Motor 852-0-2509-206-00-0 Cross-Flow Fan Ass’y RZA-0-2509-111-XX-0 Cross-Flow Fan Ass’y 852-0-2510-128-00-1 Bearing Ass’y RZA-0-0000-073-XX-0 Fan Motor RZA-0-5172-105-XX-0 PCB Ass’y RZA-0-5172-321-XX-0 PCB Ass’y RZA-0-0054-062-XX-0 Remote Controller TADIRAN BRAND RZA-0-5263-004-XX-0 Power Transformer RZA-0-5152-017-XX-0...
  • Page 29 8. SPARE PART LIST INDOOR UNIT TGI-07H ,TGI-09H ,TGI-12H...
  • Page 30 8. SPARE PART LIST OUTDOOR UNIT Key No. Part No. Description TGI-07 TGI-09 TGI-12 RZA-0-4526-056-XX-0 Compressor Ass'y RZA-0-4526-058-XX-0 Compressor Ass'y RZA-0-4526-150-00-2 Compressor Ass'y RZA-0-4525-023-XX-0 4-Way Valve RZA-0-4525-036-XX-0 4-Way Valve 852-0-4525-122-00-2 4-Way Valve 854-0-4518-138-00-1 Unilateral Valve RZA-0-2049-001-XX-0 Magnetic Coil RZA-2-2396-003-XX-0 Special Nut Ass'y (compressor) RZA-2-2390-037-XX-0 Rubber Gasket (compressor) RZA-2-2390-002-XX-1...
  • Page 31 8. SPARE PART LIST OUTDOOR UNIT TGI-07H ,TGI-09H ,TGI-12H...
  • Page 32: Control Mode

    9. CONTROL MODE Control unit features 1. Display panel 1.1 Description of the pattern. 1.2 The display screen consists of 4 LEDs,indicating : power , time set , operation and high power respectively. 1.3 Power indicator. When the airconditioner runs, the power indicator lamplights up ;...
  • Page 33 9. CONTROL MODE 3. Automatic mode. 3.1 When the remote controller is set to start the unit in the automatic mode , the airconditioner judges according to the differences between the room temperature and temperature setting and selects a run mode. Indoor temperature ≥...
  • Page 34 9. CONTROL MODE Automatic setting- room an speed setting- room an speed 0ºC Mute 0ºC Mute 1ºC 1ºC 2ºC 2ºC 3ºC 3ºC 4ºC 4ºC ≥5ºC High ≥5ºC High Outdoor fan speed Single speed motor starts or stop as soon as the compressor starts or stops. 4.4 The 4 way valve is interrupted.
  • Page 35 9. CONTROL MODE 6. Heating mode 6.1 In the heating mode , the temperature setting is determined with the remote controller . The temperature control ranges from 16 - 30ºC. 6.2 When powered on for the first time , the compressor may be started immediately.
  • Page 36 9. CONTROL MODE Automatic an speed an speed setting- room setting- room 1ºC 1ºC 2ºC Medum 2ºC 3ºC Medum 3ºC Medum 4ºC Medum 4ºC Medum 5ºC High 5ºC Medum ≥6ºC High ≥6ºC Medum 7. Defrosting mode 7.1 Frost is removed by reverse of the 4 way valve. 7.2 Conditions for entering in the defrosting mode : After the unit gets started (in the heating mode) or every time the defrosting run ends , calculated from the time when the heating run...
  • Page 37 9. CONTROL MODE 8. Fan mode When select the fan mode , only both the indoor fan and flap operate in a preset mode . If the fan speed is set to automstic , the fan runs at the low speed. 9.
  • Page 38 9. CONTROL MODE Timer function 11.1 Timer on : When set to start in the set time with the remote controller , the air conditioner enters in the timer on status.When the set time is up the air conditioner turns on and operates according to the preset conditions after receiving the signal from the remote controller .
  • Page 39: Sensor Parameters

    10. SENSOR PARAMETERS TGI-07H ,TGI-09H , TGI-12H , TGI-18H THE PARAMETER OF THE TEMPERATURE SENSOR T(C ) R(Ko) V(v) T(C ) R(Ko) V(v) T(C ) R(Ko) V(v) 23.95 0.8202 7.549 1.9185 2.936 3.0775 22.82 0.8539 7.249 1.9667 2.835 3.1188 21.75 0.8885 6.962 2.0151...
  • Page 40: Troubleshooting

    11. TROUBLESHOOTING When the control unit generates the protective action , press the sensor switch – over button , the trouble code will be displayed on the LCD screen on the indoor unit to help debug and repair : When the air conditioner gets in trouble and brings about trouble codes are tabulated below ( ☻...
  • Page 41: Disassembly Instructions

    12. DISASSEMBLY INSTRUCTIONS TGI-07H ,TGI-09H ,TGI-12H Front Panel 1 Remove the grille 1. Open the screw cover of the grille. 2. Take out the screws of the grille. 3. Hold both sides of the grille and drag it upwards by moving it around the outlet grille.
  • Page 42 12. DISASSEMBLY INSTRUCTIONS TGI-07H ,TGI-09H ,TGI-12H 4 Remove the air outlet 1. Take out the screws of the air outlet. 2. Remove the stepping motor. 3. Disconnect the drainage hose and the air outlet. 4. Remove the air outlet. Screws 5 Remove the evaporator coil 1.
  • Page 43 12. DISASSEMBLY INSTRUCTIONS TGI-07H ,TGI-09H ,TGI-12H 1 Remove the right side panel 1. Take out the screws of the side panel and remove the side panel. Screw Screws 2. Take out the screws of the right side panel. Remove the right side panel.
  • Page 44 12. DISASSEMBLY INSTRUCTIONS TGI-07H ,TGI-09H ,TGI-12H 4 Remove the electrical board 1. Disconnect all the connectors of the terminal board and the capacitor. 2. Take out the screws of the electrical board. Screw 3. Remove the electrical board. Capacitor Clip...

This manual is also suitable for:

Tgi-18hTgi-09hTgi-12h

Table of Contents