254 Parameters
No.
Name/Value
32.27
Supervision 3 signal
32.28
Supervision 3 filter
time
0.000...30.000 s
32.29
Supervision 3 low
-21474830.00
...21474830.00
32.30
Supervision 3 high
-21474830.00
...21474830.00
33
33 Generic timer &
counter
33.01
Counter status
0000 0000b...0011
1111b
33.10
On-time 1 actual
0...4294967295 s
33.11
On-time 1 warn limit
0...4294967295 s
Description
Selects the signal to be monitored by signal supervision
function 3.
For the available selections, see parameter
Supervision 1
signal.
Defines a filter time constant for the signal monitored by
signal supervision 3.
Signal filter time.
Defines the lower limit for signal supervision 3.
Low limit.
Defines the upper limit for signal supervision 3.
Upper limit.
Configuration of maintenance timers/counters.
See also section
Maintenance timers and counters
89).
Displays the maintenance timer/counter status word,
indicating which maintenance timers/counters have
exceeded their limits.
This parameter is read-only.
Bit
Name
Description
0
On-time1
1 = On-time timer 1 has reached its preset limit.
1
On-time2
1 = On-time timer 2 has reached its preset limit.
2
Edge 1
1 = Signal edge counter 1 has reached its preset limit.
3
Edge 2
1 = Signal edge counter 2 has reached its preset limit.
4
Value 1
1 = Value counter 1 has reached its preset limit.
5
Value 2
1 = Value counter 2 has reached its preset limit.
6...15 Reserved
Maintenance time/counter status word.
Displays the actual present value of on-time timer 1.
The timer runs whenever the signal selected by parameter
33.13 On-time 1 source
When the timer exceeds the limit set by
warn
limit, bit 0 of
33.01 Counter status
warning specified by
also given if enabled by
The timer can be reset from the Drive composer PC tool,
or from the control panel by keeping Reset depressed for
over 3 seconds.
Actual present value of on-time timer 1.
Sets the warning limit for on-time timer 1.
Warning limit for on-time timer 1.
32.07
is on.
33.11 On-time 1
is set to 1. The
33.14 On-time 1 warn message
33.12 On-time 1
function.
Def/
FbEq16
Zero
0.000 s
1000 = 1 s
0.00
-
0.00
-
(page
-
1 = 1
-
is
-
0 s
-