Download Print this page

netvox R718J User Manual page 9

Wireless dry contact interface
Hide thumbs Also See for R718J:

Advertisement

Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e.
BatteryVoltageChange= 0.1V.
sleeping
th
0H
15
M
Wakes up and
Wakes up and
collects data
collects data
3.6V
REPORT 3.6V
Does not report
Notes:
(1) The device only wakes up and performs data sampling according to MinTime Interval.
When it is sleeping, it does not collect data.
(2) The data collected is compared with the last data reported. If the data change value is greater
than the ReportableChange value, the device reports according to MinTime interval.
If the data variation is not greater than the last data reported, the device reports according to
MaxTime interval.
(3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is
too low, the device wakes up frequently and the battery will be drained soon.
(4) Whenever the device sends a report, no matter resulting from data variation, button pushed
or MaxTime interval, another cycle of MinTime/MaxTime calculation is started.
Wakes up and collects
data
3.5V |3.5-3.6|=0.1
REPORTS 3.5V
sleeping
th
30
M
Users push the button,
REPORTS 3.5V.
Recalculate MaxTime.
th
45
M
1H
Wakes up and
Wakes up and
collects data
collects data
3.5V
3.5V
Does not report
Does not report
8
MaxTime
Wakes up and
collects data 3.5V
Does not report
th
th
1H 10
M
1H 25
M
Wakes up and
collects data
3.5V
Does not report

Advertisement

loading