This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
Netvox and is compatible with the LoRaWAN protocol. R718PA1 can be connected to a corresponding carbon monoxide sensor (RS485) to report the concentration of carbon monoxide collected by the device to the corresponding gateway. The device is compatible with the LoRaWAN protocol.
2. Appearance CO Senser Indicator Function Key Adaptor 3. Main Feature Adopt SX1276 wireless communication module 12V DC power supply CO detection The base is attached with a magnet that can be attached to a ferrous object ...
4.Set Up Instruction On/Off Power on DC12V adapter DC12V power supply, the green indicator flashing once means turn on Turn on successfully. Turn off Press and hold the function key for 5 seconds till the green indicator (Restore to factory setting) flashes 20 times.
1. The cycle of the device sending the data report is according to the default. 2. R718PA1 reports the concentration of carbon monoxide. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index to resolve uplink data.
6.Installation 1. R718PA1 has a built-in magnet (as the figure 2. The device periodically reports the data below). It can be attached to the surface of an iron according to Max Time. The default Max object conveniently and quickly when it is installed.
7.Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits. In case the device is wet, please dry it completely. •...