Download Print this page
netvox R718PA1 User Manual

netvox R718PA1 User Manual

Wireless co sensor
Hide thumbs Also See for R718PA1:

Advertisement

Quick Links

R718PA1
Model:
Model: R718PA1
Wireless CO Sensor
Wireless CO Sensor
R718PA1
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX
Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in
whole or in part, without written permission of NETVOX Technology. The specifications are subject
to change without prior notice.

Advertisement

loading

Summary of Contents for netvox R718PA1

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ............................2 2. Appearance ............................3 3. Main Feature ............................. 3 4. Set Up Instruction ..........................4 5. Data Report ............................5 6. Installation ............................7 7. Important Maintenance Instruction ....................7...
  • Page 3: Introduction

    Netvox and is compatible with the LoRaWAN protocol. R718PA1 can be connected to a corresponding carbon monoxide sensor (RS485) to report the concentration of carbon monoxide collected by the device to the corresponding gateway. The device is compatible with the LoRaWAN protocol.
  • Page 4: Appearance

    2. Appearance CO Senser Indicator Function Key Adaptor 3. Main Feature  Adopt SX1276 wireless communication module  12V DC power supply  CO detection  The base is attached with a magnet that can be attached to a ferrous object ...
  • Page 5: Set Up Instruction

    4.Set Up Instruction On/Off Power on DC12V adapter DC12V power supply, the green indicator flashing once means turn on Turn on successfully. Turn off Press and hold the function key for 5 seconds till the green indicator (Restore to factory setting) flashes 20 times.
  • Page 6: Data Report

    1. The cycle of the device sending the data report is according to the default. 2. R718PA1 reports the concentration of carbon monoxide. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index to resolve uplink data.
  • Page 7 ConfigReport MinTime MaxTime Reserved 0x01 (2bytes Unit: s) (2bytes Unit: s) (5Bytes,Fixed 0x00) ConfigReport Status Reserved 0x81 (0x00_success) (8Bytes, Fixed 0x00) R718PA1 0x57 ReadConfig Reserved 0x02 ReportReq (9Bytes, Fixed 0x00) ReadConfig MinTime MaxTime Reserved 0x82 ReportRsp (2bytes Unit: s) (2bytes Unit: s)
  • Page 8: Installation

    6.Installation 1. R718PA1 has a built-in magnet (as the figure 2. The device periodically reports the data below). It can be attached to the surface of an iron according to Max Time. The default Max object conveniently and quickly when it is installed.
  • Page 9: Important Maintenance Instruction

    7.Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits. In case the device is wet, please dry it completely. •...