Example of ConfigureCmd
FPort:0x07
Bytes
1
CmdID
CmdID– 1 bytes
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
ConfigReport
Req
ConfigReport
Rsp
R718J
ReadConfigRe
portReq
ReadConfigRe
portRsp
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0121003C003C0100000000
Device returns:
8121000000000000000000 (configuration is successful)
8121010000000000000000 (configuration failed)
(2) Read device parameters
Downlink: 0221000000000000000000
Device returns:
8221003C003C0100000000 (current device parameters)
1
DeviceType
Cmd
Device
ID
Type
MinTime
0x01
(2bytes Unit:s)
0x81
0x21
0x02
MinTime
0x82
(2bytes Unit:s)
Var(Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MaxTime
(2bytes Unit:s)
Status
(0x00_success)
Reserved
(9Bytes,Fixed 0x00)
MaxTime
(2bytes Unit:s)
003C(H
= 60(D
ex)
ec)
6
Reserved
BatteryChange
(4Bytes,Fixed
(1byte Unit:0.1v)
Reserved
(8Bytes,Fixed 0x00)
Reserved
BatteryChange
(4Bytes,Fixed
(1byte Unit:0.1v)
0x00)
0x00)