A.2.11

Energy management

Only read access (r) to the energy management is possible via Function Codes 03 and 04.
Register
Address
hex
dec
0x09C1
2497
0x09C3
2499
0x09C5
2501
0x09C7
2503
0x0A47
2631
0x0A61
2657
Supported by SIRIUS 3RW50 and 3RW52 soft starters
1)
Supported by SIRIUS 3RW55 and 3RW55 Failsafe soft starters
2)
SIRIUS 3RW5 Modbus communication module
Equipment Manual, 03/2020, A5E43676481002A/RS-AC/003
Data format
Quantity
2
Float32
2
Float32
2
Float32
2
Float32
2
Float32
2
Float32
Content
Phase current I L1 (rms)
Phase current I L2 (rms)
Phase current I L3 (rms)
Phase current average (rms)
Active power
Active energy import (total)
Appendix
A.2 Data tables
Unit
3RW
50 /
55 /
52
55-F
1)
2)
A
r
r
A
r
r
A
r
r
A
r
r
W
-
r
Wh
-
r