Item
Operating
Temperature
Storage
Operating
Humidity
Storage
Ambient light immunity
Vibration
Drop
Dust and drip proof
LED safety
EMC
European conformity
No destruction
Electrostatic
discharge
No malfunction
Radiated radio
Frequency
frequency
Level
electromagnetic
AM
Field immunity
Power frequency
magnetic field
LEVEL
immunity
SPECIFICATIONS MANUAL
Specification
-5 to 50°C
-20 to 60°C
10 to 90% (No condensing, no frost)
5 to 95% (No condensing, no frost)
10,000 lx or less
Increase the frequency of the vibration
from 10 Hz to 100 Hz at an accelerated
2
velocity of 19.6m/s
for 60 minutes once
each in X, Y and Z-direction
Drop the scanner 18 times (6 faces x 3)
from the height of 75 cm onto a concrete
floor
IP65 equivalent
IEC 62471 Exempt Risk Group
VCCI クラス B / FCC Class B / EN 55032
Class B, EN 55024
CE marking
Contact discharge (direct / indirect): ±8 kV
Air discharge (direct): ±15kV
Contact discharge (direct / indirect): ±4 kV
Air discharge (direct): ±8kV
80 to 1000 MHz
3 V/m
80% (AM)
1A/m
NLV-4001
2nd
Note
JAN-13 (resolution
0.26 mm) DOF 59 mm
* Excluding the part
where the interface
cable is attached
For residential,
commercial and light-
industry environments
Conditions:
IEC61000-4-2
compliant
Conditions:
IEC61000-4-3
compliant
Conditions:
IEC61000-4-8
compliant