Download Print this page

Opticon NLV-4001 Specification Manual page 31

Ccd barcode scanner

Advertisement

15.3 Default Setting (Part 2: Read Options, Illumination LED, Trigger, Buzzer)
Setting of number of characters
Read mode
Multiple read reset time
Add-on wait mode
Multiple label read (code only)
Multiple column read
Redundancy (*1)
Illumination LED
Trigger repeat
Read time
Margin check
Buzzer duration
Buzzer tone
Buzzer loudness
Buzzer timing
Startup buzzer
Status LED duration
(*1) The redundancy count for the following specific digits of bar codes will be
[the set number of times + 1].
Symbology
Code 39
Codabar(NW-7)
IATA
Industrial 2 of 5
Interleaved 2 of 5
MSI/Plessey
Code 11
TELEPEN
S-Code
Matrix 2 of 5
Chinese Post Matrix 2 of 5
SPECIFICATIONS MANUAL
Item
Default
Off all codes
Single read
500 msec
500 msec
Disable
Disable
Read 1 time (redundancy = 0)
Enable
Disable
2 sec
Normal
50 msec
3 kHz (single tone)
Volume 1 (Maximum.)
Before transmission
Enable
200 msec
No. of Digits
5 or less
All
8 or less
8 or less
8 or less
4 or less
5 or less
8 or less
7 or less
8 or less
8 or less
NLV-4001
2nd
25

Advertisement

loading