IDEC HS5E Series Manual page 12

Miniature solenoid locking switches
Hide thumbs Also See for HS5E Series:
Table of Contents

Advertisement

Actuator Angle Adjustment
• Using the screw (M3 hex socket head screw), the actuator angle can be
adjusted (refer to the dimensional drawing). Adjustable angle: (0˚) to 20˚
• The larger the adjusted angle of the actuator, the smaller the applicable
radius of the door opening.
Minimum Radius of Hinged Door
• When using the interlock switch on hinged doors, refer to the minimum radius
of doors shown below. When using on doors with small minimum radius, use
the angle adjustable actuator (HS9Z-A55).
Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure
of the correct operation before installation.
When using the HS9Z-A52 Actuator
• When the door hinge is on the extension line of the interlock switch surface:
Door Hinge
• When door hinge is on the extension line of the actuator mounting surface:
Door Hinge
When using the HS9Z-A55 Angle Adjustable Actuator
• When door hinge is on the extension line of the interlock switch surface:
50 mm
• When door hinge is on the extension line of the actuator mounting surface:
70 mm
Use a cable gland with a degree of protection IP67
G1/2, PG13.5, M20
9 max.
When Using Flexible Conduits (Example)
Flexible conduit example: VF-03 (Nihon Flex)
Conduit Port Size
Plastic Cable Gland
G1/2
PG13.5
M20
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Door Hinge
Door Hinge
Applicable Cable Glands
all dimensions in mm
Metal Cable Gland
RLC-103 (Nihon Flex)
RBC-103PG13.5 (Nihon Flex)
RLC-103EC20 (Nihon Flex)
• After installing the actuator, open the door. Then adjust the actuator so that
its edge can be inserted properly into the entry slot of the safety switch.
• Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm)
• After adjusting the actuator angle, apply loctite or the like to the adjustment
screw so as to prevent its loosening.
Horizontal Swing
Door Hinge
Vertical Swing
Door Hinge
Actuator Angle Adjustment for the HS9Z-A55
• Using the angle adjustment screw, the actuator angle can be adjusted (see
figures on page 370. Adjustable angle: 0 to 20°
• The larger the adjusted angle of the actuator, the smaller the applicable
radius of the door opening.
• After installing the actuator, open the door. Then adjust the actuator so that
its edge can be inserted properly into the actuator entry slot of the interlock
switch.
• After adjusting the actuator angle, apply Loctite to the adjustment screw so
that the screw will not loosen.
When Using Multi-core Cables (Example)
Conduit Port Size
Plastic Cable Gland
G1/2
SCS-10*
(Seiwa Electric)
PG13.5
ST13.5
(K-MECS)
M20
ST-M20X1.5
(K-MECS)
Different cable glands are used depending on the cable sheath outside diameter. When
purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath
outside diameter.
When using a 1/2-14NPT cable gland, use the HS5B interlock switch with M20 conduit
port (Part No.: HS5B-***BM) together with an adapter (Part No.: MA-M/NPT 20X1.5
5402-0110, K-MECS) and a gasket (Part No.: GP M20, K-MECS). Install a gasket between
the interlock switch and the adapter. Apply sealing tape between the cable gland and
the adapter to make sure of IP67 protection for the enclosure.
Door Hinge
Door Hinge
Metal Cable Gland
ALS-16**
(Nihon Flex)
ABS-**PG13.5
(Nihon Flex)
ALS-**EC20
(Nihon Flex)

Advertisement

Table of Contents
loading