– Connect the brakes to the hydraulic system.
Specifications:
•
•
•
•
•
7 – 2
Verification procedure
– When the cylinder is depressurised, measure the distance between the outer surface of the
– If once the cylinder is depressurised the brake shoe is up against the bottom of the slot, this
7 – 3
Brake adjustment
A system is provided to check whether a brake adjustment is needed. The position of the pins
(framed in red) shows how much the brakes are worn.
Closed braking system
Min. pressure: 55 bar
Max. pressure: 100 bar
Flow rate: 10 l/min
DN10 hose
washer and base of the shoe. This must measure 67 mm. If not, carry out the brake adjust-
ment procedure (see 7.3).
indicates maximum wear (see 7.4).
POSITION BEFORE WEAR