Clearances around the equipment must be checked before operating. No extrane- ous objects must be placed under the equipment. MAKE SURE that neither fork nor load snag extraneous objects during lifting and lowering. Logiflex / Logilift See also the instruction manual.
2.0 Operating and functions The brake must be activated before the equipment can be used. Push ON Logiflex / Logilift can start lifting/lowering Manual operating on the handle is not possible when level control is active...
Page 4
Diode On/off Green lamp for ON Down Load: Unload:...
3.0 Time delay Max. 3 mm 1 2 3 ..10 sec. 0-10 seconds’ delay of lifting/lowering operation. 4.0 Function range The function range is between 550 mm and 900 mm. Adjustment of function range.
Page 6
5.0 Photocell The detection range of the pho- tocell can be adjusted up to 1000 mm for white items and 800 mm for black items. The shortest range is approx. 200 Adjustment of the detection range mm for white items. (of the photocell) 1000 mm 200 mm...
6.0 Battery condition NB! To get optimum function of the equipment, battery charge should not be below 25%. <25% 100% Discharged Final Charge...
Page 8
7.0 Optional side mounting 2 screws on centre tube 2 screws on the control box Remove 2 x 2 screws Change the slide to opposite hand Refit 2 x 2 screws...
Page 9
8.0 Adjustment Adjustment is necessary if the motor does not stop before the top position and the distance between pallet and underlay (or floor) is less than 100 mm. Adjustment of top and bottom stop for forks Moves the top stop up or down. Max.
9.0 Replacement of fuse Examine the fuse. Part number 986066 (ø5 X 20, 250V 4A T)
Page 11
10.0 Fault location key After a certain time, adjustments can be necessary. BEFORE CONTACTING THE DEALER FOR HELP..TRY USING THE FAULT LOCATION KEY! Symptoms and observations: SWITCHES: Lamp works but no reaction. The lamp does not work and the equipment does not react. SLIDE: Does not slide up and down with the forks.
Page 12
Cause Remedy Contact Check photocell setting dealer Contact Check brake and brake switch dealer Check for cable fracture Examine fuse. Check for obstructions Check for dirt and uncleannesses on the centre tube Check spring tension in slide Adjust photocell range Adjust photocell direction across pallet Check condition of battery...
Page 13
Periodic safety inspection Safety inspection should be performed by the supplier or other qualified persons at least once each year, unless local regulations state otherwise. Such inspection shall be performed in accordance with the instruction manual. Test instructions and test forms are available from the distributor. Pos-LLTE-ELF-EN S655 220506/02...