Page 2
EU DECLARATION OF CONFORMANCE Manufacturer: Logitrans A/S Hillerupvej 35 DK-6760 Ribe Danmark It is hereby declared that: Machine: Product group: Stackers Type: EHS 1000 RF Year of manufacture/ Serial No.: Has been manufactured in conformance with the stipulations of the •...
Page 3
1.0 Before the first lift... The Logitrans Stacker is manufactured in accordance with safety directives. Among the subjects dealt with in this Instruction Manual are: - Proper application - Physical limitations of the product - Risks with improper use - Therefore please read this Instruction Manual carefully!
Page 4
2.0 How to operate the stacker STACKER APPLICATION - PALLET HANDLING - For proper operation, stand behind the handle. Push/pull - raise/lower...
3.0 Optimum safety 3.1 Avoid overloads The maximum load must not be exceeded. Remember, the stacker is designed for evenly distributed load, - goods on pallets etc. If the for- ks are pointloaded on one side there is a risk of bending. 3.2 Avoid offset loads The load must be evenly distributed.
3.3 Driving loaded The stacker is designed for use on even and level floor. During trans- port the forks shall be raised as little as possible. Transport with raised forks should be made over the shortest possible distances and at low speed.
Safety regulations - Never walk under a raised load! - Before lowering the forks, make certain that no foreign elements can hinder the free lowering of the forks. - The stacker is designed for use on even and level floor. - During transport the forks shall be raised as little as possible.
3.5 Safety system Fuses: motor protector and protection against electrical overload. Safety/pressure relief valve: protection against mechanical and hydraulic overload. Set by the manufacturer at the maxi- mum design load (see product nameplate). Hose safety valve: protection against load "falling" in the event of hose fracture.
4.0 There must be a current supply 4.1 Battery specifications The manufacturer offers two different battery types recommended for EHS 1000: Semi-trak Semi-trak Tubular cell 986034 986036 986014 Voltage 60Ah/5h 105Ah/5h 113Ah/5h Capacity 74Ah/20h 130Ah/20h 130Ah/10h Recommended for Normal use Severe daily use Life in cycles at Approx.
4.2 Checking the battery Method A for SEMI-TRAK and TUBULAR CELL: Check acid density in the six battery cells with an acidometer. Check each cell - max. difference between each cell 0.04 kg/l. DENSITY 1.26 - 1.28 kg/l Fully charged 1.19 - 1.20 kg/l 1/2 charged 1.16 - 1.17 kg/l...
4.5 Fuses - replacement There are two fuses in the electrical circuit. - See illustration under point 3.5: 80 amp fuse in main supply from battery (location: see A1, point 3.5) 5 amp fuse in control current circuit (location: see A2, point 3.5) Replacement: Before replacing fuse, disconnect battery + pole.
5.0 Long live the stacker Regular inspection and the replacement of worn or defective parts in good time will prolong the life of the stacker. "Prevention is better than repair", therefore ensure: Correct usage Regular cleaning Oil changes at the correct intervals Periodic safety inspection 5.1 Lubrication and oil change Galvanised, semi stainless and stainless electrical products:...
5.3 Fork adjustment Two of the rollers on the fork bracket are mounted on eccentric pins so that they can be adjusted. The adjustable rollers are upper most. Loosen setscrews pos. 91 (5 mm a/flats). Eccentric pin pos. 56 (8 mm a/flats) can now be turned to give the necessary fork adjustment.
5.5 Adjustment of steer wheel chain Access to the chain is gained by removing the chain guard. -Remove the two screws (111) and two screws(110) (4 mm Allen key). -Set the handle in its mid position. -Adjust nuts (1 and 2, 3 and 4) and bring the wheels into parallel.
Control list and specifications concerning service and safety check can be ordered from Logitrans dealers. 6.5 Liability exemption The manufacturer accepts no responsibility for personal injury or material damage arising from deficiencies, defects or improper usage.
Page 16
7.0 The advantages of stainless 7.1 Corrosion in EHS Stainless Details are contained in the spare parts lists. A B C D Chassis Handle Fork bracket Cylinder (1) Brake Shafts...
Page 17
Material code Acid-resistant steel AISI 316 Stainless steel AISI 303/304 Hot-dip galvanised - coating thickness: min. 50 µm Electrogalvanised + yellow chromated - coating thick- ness: 6-10 µm. - This surface treatment has good properties in respect of wear, water and chemical resistance. However, it is important to be aware that if certain parts are subjected to shock and impact the coating can crack and thus allow corrosive substances to affect base...
Page 18
8.0 Fault location key When the STACKER is used every day, adjustments and the replacement of worn parts might be necessary. If a fault appears during daily operation of the highlifter, first check: Oil supply Electricity supply Condition of leads and fuses If faults cannot be traced to these sources, contact your distributor, but ..
Page 19
Cause Mending See point 5.1/ Oil deficiency Battery discharged See point 4.3 Fuse blown See point 3.5/ Point 3.5 pos. A1/A2 See point 4.6 Leads defective Max. load exceeded See point 3.1 Air in hydraulic system See point 5.6 Contact the Pressure relief valve incorrectly distributor adjusted Point 3.5 pos.
Page 20
Such inspection shall be performed in accordance with the instruc- tion manual. Test instructions and test forms are available from the distributor. WWW.L .L .L .L .LOGITRANS.COM OGITRANS.COM OGITRANS.COM OGITRANS.COM OGITRANS.COM...