Advertisement

LOGIFLEX SELF MAXI / SELFS MAXI

Advertisement

Table of Contents
loading

Summary of Contents for logitrans LOGIFLEX SELF MAXI

  • Page 1 LOGIFLEX SELF MAXI / SELFS MAXI...
  • Page 2 • EN 3691-1 Responsible for the technical dossier: Name: Gitte Kirkegaard Address: Hillerupvej 35, DK-6760 Ribe Signature: Gitte Kirkegaard, CEO, Logitrans A/S Ribe, 01.10.2018 B148 D152-3 - 2 -...
  • Page 3: Table Of Contents

    Contents 1.0 Before the first lift....................4 2.0 Functions and identifications ................5 3.0 How to operate the Logiflex Maxi ..............6 3.1 Handling of pallets ....................... 6 3.2 Handle functions ........................8 3.3 Emergency stop........................9 4.0 Optimum safety .....................
  • Page 4: Before The First Lift

    1.0 Before the first lift... The Logiflex Maxi is manufactured in accordance with safety directives. Among the subjects dealt with in this Instruction Manual are: • Proper application • Physical limitations of the product • Risks with improper use Therefore please read this Instruction Manual carefully! - 4 -...
  • Page 5: Functions And Identifications

    2.0 Functions and identifications 1. Safety Switch 2. Horn 3. Lift/Lower 4. Forward/Reverse 5. Multiflex Function 6. Handle 7. Battery indicator / hour counter 8. Emergency Stop 9. Ignition Key 10. Charger plug (external charger) 11. Charging Lamps (built-in charger) Identifications Battery label (below the cover) Name plate, serial number Capacity plate...
  • Page 6: How To Operate The Logiflex Maxi

    3.0 How to operate the Logiflex Maxi 3.1 Handling of pallets For proper operation, stand behind the handle! The forks will lift 190 mm before the telescopic mast begins to extend. (SELF Maxi 2050 - 3300) (SELFS Maxi 2020 - 3270) SELFS Maxi When handling closed pallets...
  • Page 7 3.0 How to operate Logiflex Maxi Insert key (1) and turn clockwise to switch on control current ready for function activation. Note!!! Emergency stop (2) must not be activated. The control functions of the stacker are located in the handle (3). - The functions are dependent on the positions of the handle! Position A: Drive position Drive current on...
  • Page 8: Handle Functions

    3.0 How to operate the Logiflex Maxi 3.2 Handle functions - 8 -...
  • Page 9: Emergency Stop

    3.0 How to operate the Logiflex Maxi 3.2 Handle functions Multiflex Function Multiflex Function • This function makes it possible to drive the stacker, even though the handle is in its upright, braked position • The function requires two-handed operation, i.e. it must be performed deliberately •...
  • Page 10: Optimum Safety

    4.0 Optimum safety ATTENTION Moving parts Safety regulations • Never walk under a raised load! • Before lowering the forks, make certain that no foreign elements can hinder the free lowering of the forks. • Logiflex Maxi is designed for use on an even and level floor. • During transport the forks shall be raised as little as possible. •...
  • Page 11: Marking

    4.0 Optimum safety 4.1 Marking The mast lifting capacity and the corresponding centre of gra- vity distance are given by the pictogram on the side of the mast. The lifting capacity of the mast is the same as the max. lifting capacity of the product.
  • Page 12: Personal Safety

    4.0 Optimum safety 4.0 Optimum safety 4.2 Personal safety 4.2 Personal safety The safety switch on the end of the handle ensures that the operator cannot be The safety switch on the end of the handle ensures that the operator cannot be trapped when the stacker is reversed.
  • Page 13: Transport With Load

    4.0 Optimum safety 4.3 Transport with load The load centre is never allowed to exceed the center line of the wheels. The driving speed is reduced when lifting the forks above 400 mm. The Logiflex Maxi is designed for use on even and level floor. During transport the forks shall be raised as little as possible. Transport with raised forks should be made over the shortest possible distances and at low speed.
  • Page 14: There Must Be A Current Supply

    5.0 There must be a current supply... 5.1 Fuses - replacement There are 5 fuses in the electrical circuit, located behind Sikringer the plate with this pictogram. Fuses Fusibles Sicherungen A) 40 Amp fuse (only when optional extras) B) 100 Amp fuse for lifting motor C) 100 Amp fuse for driving motor D) 10 Amp fuse in the control current circuit E) 20 Amp fuse for built-in charger...
  • Page 15: Long Live The Logiflex Maxi

    6.0 Long live Logiflex Maxi Regular inspection and the replacement of worn or defective parts in good time will prolong the life of the Logiflex Maxi. “Prevention is better than repair”, therefore ensure: Correct usage Regular cleaning Periodic safety and service inspection (see the back page) Due to safety reasons, the below points have to be checked every 3 months: - Loose screws and nuts have to be tightened up.
  • Page 16: Oil Change

    6.0 Long live Logiflex Maxi... 6.2 Oil change Draining the oil: 1. Bring the unloaded forks down to the lowest position. 2. Most of the oil can be drained by loosening the hydraulic hose union in the bottom of the cylinder. Activate the hydraulic pump by pressure on the switch. The oil will run out.
  • Page 17: Hydraulic Pump

    6.0 Long live Logiflex Maxi... 6.3 The hydraulic pump The hydraulic pump has a S3 “periodic intermittent duty” of 10%. This means that the pump in total is allowed to operate 1 minute for a period of 10 minutes. Note! If the pump operates more than 10%, the motor will be damaged due to superheating.
  • Page 18: Fork Adjustment

    6.0 Long live Logiflex Maxi... 6.5 Fork adjustment Two of the rollers on the fork bracket are mounted on eccentric pins, so that they can be adjusted. The adjustable rollers are at the top. 1. Loosen screw (pos. 91) (key width 5 mm). 2.
  • Page 19: Adjustment Of Side Play

    6.0 Long live Logiflex Maxi... 6.7 Adjustment of side play (In the mast rolls of the right side of the fork bracket) 1: Screw (A) is loosened counter-clockwise, until resistance disappears. 2: Turn the screw clockwise, until resistance appears. The following 1.5 to 2.5 turns of the screw will be a tightening of the spring (C).
  • Page 20: Fault Location Key

    7.0 Fault location key When the Logiflex is used every day, adjustments and the replacement of worn parts might be necessary. Adjustments and minor repairs can easily be made on the spot. Major repairs should, however, be carried through by the dealer who has a well-trained staff and the necessary special tools. Before asking the dealer for assistance...
  • Page 21 Cause Remedy Inadequate power supply Battery discharged Fault in on/off switch Fault in control current circuit Fault in main/power current circuit Too little current on battery No current on brake Brake needs adjusting Insufficient oil in tank. Load too heavy, safety valve is set wrongly No current on solenoid valve Oil circuit leakage...
  • Page 22: Remedy

    7.0 Fault location key 7.1 Remedy 1) Check to ensure that the key (A) is turned clockwise and that emergency stop (B) is not activivated. 2) Charge battery - (see separate instruction manual for battery and charger) Access to the battery is achieved by tipping the cover (C). - If necessary, check the liquid level in battery cells.
  • Page 23 7.0 Fault location key - 23 -...
  • Page 24: Good Service After Purchase

    The warranty covers material and assembly defects which, subject to inspection by us or our representative, are deemed to be faults or deficiencies that prevent normal use of the parts concerned. Such affected parts shall be sent to your Logitrans dealer carriage paid within the warranty period in force at the time in question, together with a copy of the documentation for the service performed (B284 - see the back page).
  • Page 25 - 25 -...
  • Page 26 - 26 -...
  • Page 27 - 27 -...
  • Page 28 Periodic service check Service check is required once each year, or at least for every 500 hours of operation. The service check is to be performed on the basis of form no. B280 and proved on form no. B284. Forms and instructions for the service check are available at your dealer.

This manual is also suitable for:

Logiflex selfs maxi

Table of Contents