Pulses Per 400 Feet; Width - Landoll 5110NG Operator's Manual

Native grass drill
Table of Contents

Advertisement

Pulses per 400 Feet

Press the FUNC button until the "PULSES" LED is lit.
The number in the display indicates how many pulses are
generated for every 400 feet driven.
1. For the 5110NG Grain Drill, set the pulses per 400
feet to 17 by using the UP and DOWN buttons. When
you press the FUNC button, the Acre Counter will
accept the number in the display as the new pulses
per 400 feet.
NOTE
If a password is set, you will not be able to adjust the
pulses per 400 feet.
Acre Counter
FIELD
TOTAL PULSES WIDTH P-WORD BATT
ACRES
*
Figure 4-48: Pulses per 400 Feet Adjustment
See Figure
4-48.
17
OPERATION AND MAINTENANCE

Width

1. Press the FUNC button until the "WIDTH" LED is lit.
The number displayed is the length of your
implement in feet
See Figure
2. To adjust the width, press the UP and DOWN
buttons. If a password has been entered, you will not
be able to adjust the width.
3. The width can be adjusted from .1 to 99.9 feet, in
tenths of a foot.
Acre Counter
FIELD
TOTAL PULSES WIDTH P-WORD BATT
ACRES
*
Figure 4-49: Drill Width
4-49.
40.0
4-43

Advertisement

Table of Contents
loading

Table of Contents