INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS CENTRIFUGAL PUMP HYGINOX SE Original instructions 01.011.30.07EN (0) 2019/09...
Page 2
Applicable harmonized standards: EN ISO 12100:2010 EN 809:1998+A1:2009/AC:2010 EN 60204-1:2006+A1:2009 The technical file has been prepared by the signer of this document in INOXPA. Signed by and on behalf of INOXPA S.A.U. David Reyero Brunet Technical Office Manager Banyoles, September 30, 2019...
• risk to the environment due to the type of substances released. 2.3. WARRANTY Any warranty will be void immediately and lawfully and, additionally, INOXPA will be compensated for any civil liability claims submitted by third parties, in the following cases: •...
Important instruction for the protection of the equipment and its functions ATTENTION 3.2. GENERAL SAFETY INSTRUCTIONS Read the instruction manual carefully before installing and starting the pump. Contact INOXPA in case of doubt. 3.2.1. During the installation Technical Specifications of chapter 9 should always be observed.
The range of application for each type of pump is limited. The pump was selected for a given set of pumping conditions when the order was placed. INOXPA shall not be liable for any damage resulting from the incompleteness of the information provided by the purchaser (nature of the fluid, RPM, etc.).
Installation 5. Installation 5.1. RECEPTION OF THE PUMP INOXPA cannot be held responsible for the damage sustained by the equipment during transport or unpacking. Please visually check that the packaging is not damaged. The pump package includes the following documents: •...
If the pump is installed outdoors, it should be covered by a roof. Its location should allow easy access for inspection or maintenance operations. 5.4.1. Excessive temperatures Depending on the fluid to be pumped, high temperatures can be reached inside and around the pump. INOXPA S.A.U. · 01.011.30.07EN · (0) 2019/09...
See from the rear of the motor ATTENTION See indicator label on the pump. ALWAYS check the direction of rotation of the motor with liquid inside the pump. · INOXPA S.A.U. 01.011.30.07EN · (0) 2019/09...
Prior to starting the pump, carefully read the instructions in chapter Installation. Carefully read section 9. Technical Specifications. INOXPA will not be liable for improper use of the equipment. NEVER touch the pump or the lines if hot liquids are being pumped. 6.1. CHECKS BEFORE STARTING THE PUMP ...
Page 11
Start-up Use special protection when the sound pressure in the operation area exceeds 85 dB(A). · INOXPA S.A.U. 01.011.30.07EN · (0) 2019/09...
The following table provides solutions to problems that might arise during the operation of the pump. The pump is assumed to have been properly installed and be suitable for the relevant application. Please contact INOXPA if technical assistance is required. Motor overload...
8.5. CLEANING The use of aggressive cleaning products such as caustic soda and nitric acid may give raise to skin burns. Use rubber gloves during cleaning procedures. Always use protective goggles. · INOXPA S.A.U. 01.011.30.07EN · (0) 2019/09...
Page 14
Maximum conditions during SIP process with steam or overheated water: a) Maximum temperature: 140°C / 284°F b) Maximum time: 30 min c) Cooling: sterile air or inert gas d) Materials: EPDM/PTFE (recommended) FPM/NBR (not recommended) INOXPA S.A.U. · 01.011.30.07EN · (0) 2019/09...
Incorrect assembly or disassembly may cause damage in the pump’s operation and lead to high repair costs and a long period of down time. INOXPA is not responsible for accidents or damages cause by a failure to comply with the instructions in this manual.
Page 16
12. Mount the O-ring (80A) on the pump cover (03) taking care that it is not twisted 13. Punt the pump casing (01) and secure it on the lantern (04) by the casing clamp (15) and tighten the clamp nut tightly. INOXPA S.A.U. · 01.011.30.07EN · (0) 2019/09...
AISI 316L Other stainless steel parts AISI 304L Seals in contact with the product EPDM (standard) Other materials for the seal consult with INOXPA Exterior surface finish matt Ra ≤ 0,8 μm Interior surface finish Mechanical seal Type of seal:...
EPDM O-ring Lantern joint EPDM Splash ring EPDM Motor Parts only for pumps with motor sizes 132 and 160: Position Description Quantity Material Counterflange Hexagonal screw Flat washer Recommended spare parts · INOXPA S.A.U. 01.011.30.07EN · (0) 2019/09...