  • Page 1 INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS HYGINOX SE INOXPA, S.A. c/Telers, 54 Aptdo. 174 E-17820 Banyoles Girona (Spain) Tel. : (34) 972 - 57 52 00 Fax. : (34) 972 - 57 55 02 email: inoxpa@inoxpa.com www.inoxpa.com 01.011.30.05EN (0) 2015/01...
  • Page 2 INOXPA, S.A. c/ Telers, 57 17820 Banyoles (Girona), Spain herewith declares that the machine: HYGINOX SE centrifugal pump with the serial number: ________________ conforms to the relevant provisions of the following directives: Machinery Directive 2006/42/EC (RD 1644/2008) Low voltage Directive 2006/95/EC...
  • Page 3: Safety

    Mandatory to ensure safety at the workplace Mandatory use of safety goggles 1.4. GENERAL SAFETY INSTRUCTIONS Read the instruction manual carefully before installing and starting the pump. Contact INOXPA in case of doubt. 1.4.1. During the installation Technical Specifications of Chapter 8 should always be observed.
  • Page 4 · Risk to the environment due to the type of substances released. 1.4.5. Warranty Any warranty will be void immediately and lawfully; additionally, INOXPA will be compensated for any civil liability claims submitted by third parties, in the following cases: ·...
  • Page 5 The usage of other parts will relieve the manufacturer of any liability. Changing the service conditions can only be carried out with prior written authorisation from INOXPA Please do not hesitate to contact us in case of doubts or if further explanations are required regarding specific data (adjustments, assembly, disassembly, etc.).
  • Page 6: Table Of Contents

    7.3. Cleaning........................13 7.4. Assembly / disassembly of the pump ................15 Technical Specifications 8.1. Technical Specifications ....................17 8.2. Tightening torques ....................... 17 8.3. Cross section HYGINOX SE ................... 18 8.4. HYGINOX SE parts list ....................19 2.Table of contents 2015/01...
  • Page 7: General Information

    3.2. APPLICATION As a general rule, HYGINOX SE pumps in their standard version are used in the food industry mainly to transfer liquids. For each type of the pump, the hydraulic performance is given by the choice of impeller diameters and speeds. The characteristic curves also show the power and NPSH requirements.
  • Page 8: Installation

    4. Installation 4.1. RECEPTION OF THE PUMP INOXPA will not be liable for any deterioration of the material due to transport or unpacking. Visually check that the packaging has not been damaged. The following documentation is included with the pump: ·...
  • Page 9: Transport And Storage

    4.2. TRANSPORT AND STORAGE The HYGINOX SE pumps are often too heavy to be stored manually. Lift the pump as indicated below: ATTENTION! Always remove the motor shroud before hoisting. 4.3. LOCATION Place the pump in a position that allows enough space around it to provide access to the pump as well as to the Technical Specifications motor.
  • Page 10: Electrical Installation

    4.5. ELECTRICAL INSTALLATION Only qualified personnel can connect the electric motors. Take the necessary measures to prevent damage to cables and connections. Electrical equipment, terminals and components of the control systems may still carry current when they are disconnected. Contacting them may impose a hazard to operators or cause irreparable material damage.
  • Page 11: Starting The Pump

    5.1. START-UP T echnical Specifications Carefully read Section 8. . INOXPA will not be liable for improper use of the equipment. NEVER touch the pump or the lines if hot liquids are being pumped. 5.1.1. Checks before starting the pump ·...
  • Page 12: Operating Problems

    The attached table lists solutions to problems that may arise while operating the pump. It is assumed that the pump has been properly installed and that is has been selected correctly for the specific application. Contact INOXPA if technical assistance is required. Motor overload The pump flow or pressure is insufficient.
  • Page 13: Maintenance

    7. Maintenance 7.1. GENERAL CONSIDERATIONS This pump, just like any other machine, requires maintenance. The instructions contained in this manual cover the identification and replacement of spare parts. The instructions are aimed at maintenance personnel and those responsible for the supply of spare parts. Carefully read Chapter 8.
  • Page 14 Check the concentration of the cleaning solutions; incorrect concentrations may lead to deterioration of the pump seals. To remove any traces of cleaning products, ALWAYS perform a final rinse with clean water at the end of the cleaning process. 7.3.2. SIP (Sterilization-in-Place) cleaning Sterilization with steam is applied to all equipment including the pump.
  • Page 15: Assembly / Disassembly Of The Pump

    7.4. ASSEMBLY / DISASSEMBLY OF THE PUMP 7.4.1. Pump and single mechanical seal Disassembly Remove the clamping ring (15) and disassemble the pump casing (01). Check the condition of the O-ring (80) on the pump casing and replace if damaged. Place an open-end wrench on the flat sides of the shaft (05) to prevent it from rotating.
  • Page 16 Assembly Place the shaft (05) on the motor (93). Fix the shaft (05) with the studs (55) to the motor (93) leaving it to gauge the impeller (02) with the pump cover (03). Enter the pump cover (03) on the centering lantern (04).
  • Page 17: Technical Specifications

    8. Technical Specifications 8.1. TECHNICAL SPECIFICATIONS Maximum operating pressure 1000 kPa (10 bar) Temperature range -10 to 120 °C (EPDM) Maximum speed 3000 rpm (50 Hz) 3600 rpm (60 Hz) Materials Parts in contact with the product AISI 316L (1.4404) Other steel parts AISI 304L (1.4306) Gaskets in contact with the product...
  • Page 18: Cross Section Hyginox Se

    8.3. CROSS SECTION HYGINOX SE 8.Technical Specifications 2015/01...
  • Page 19: Hyginox Se Parts List

    8.4. HYGINOX SE PARTS LIST Description Position Quantity Material Pump casing AISI 316L Impeller AISI 316L Pump cover AISI 316L Lantern AISI 304 Shaft AISI 316L Motor leg AISI 304 Adjustable leg AISI 304 Mechanical seal Shroud AISI 304 Casing clamp...