Advertisement

Quick Links

INSTALLATION, SERVICE AND MAINTENANCE
ANNEX FOR CE ATEX REGISTERED EQUIPMENT UNDER DIRECTIVE
The contents of this Annex complement the information included in the instruction manual.
The instructions in this Annex must be observed whenever equipment registered under
Directive 2014/34/EU is used.
This annex is to be added to the manuals of the ATEX-certified components that form part
of the assembly (e.g. motors, etc).
INSTRUCTIONS
2014/34/UE:
HYGINOX Ex SE
INOXPA, S.A.U.
Telers, 60 Aptdo. 174
17820-Banyoles
Tel.: +34 972 57 52 00
Fax: +34 972 57 55 02
inoxpa@inoxpa.com
www.inoxpa.com
Manual Original
01.011.30.06EN
(C) 2022/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYGINOX Ex SE and is the answer not in the manual?

Questions and answers

Summary of Contents for INOXPA HYGINOX Ex SE

  • Page 1 INSTRUCTIONS ANNEX FOR CE ATEX REGISTERED EQUIPMENT UNDER DIRECTIVE 2014/34/UE: HYGINOX Ex SE The contents of this Annex complement the information included in the instruction manual. The instructions in this Annex must be observed whenever equipment registered under Directive 2014/34/EU is used.
  • Page 2 01.011.30.13EN (0) 2022/11 EU Declaration of Conformity INOXPA, S.A.U. Telers, 60 17820 – Banyoles (Girona) Hereby declare under our sole responsibility that the machine CENTRIFUGAL PUMP Designation HYGINOX Type IXXXXXXXXX IXXXXXXXXX From serial number Is in compliance with applicable provisions of the following directive:...
  • Page 3: Safety

    The limits of the operating conditions in explosive atmospheres must not be exceeded. This pump was selected according to the operating conditions specified by the user. Therefore, INOXPA disclaims liability for any damage caused by use of the pump in conditions other than those stated in the order. 1.3.3. During maintenance Danger! Important indications regarding protection from explosions An explosive atmosphere may be created during disassembly of the pump.
  • Page 4 1.3.4. Compliance with the instructions Any non-fulfilment of the instructions may result in a risk for the operators, the environment and the machine, and may result in the loss of your right to claim damages. Non-fulfilment may cause the following risks (in addition to those indicated in the manual): Creation of explosive atmospheres and risk of explosion.
  • Page 5: Table Of Contents

    2. Table of Contents 1. SAFETY ............................2 1.1. Instructions for starting up ....................2 1.2. Safety ..........................2 1.3. General safety instructions ....................2 2. TABLE OF CONTENTS ........................4 3. GENERAL INFORMATION ......................5 3.1. Description ........................5 3.2.
  • Page 6: General Information

    3. General information 3.1. DESCRIPTION The motors of the HYGINOX SE centrifugal pumps must be suitable for operating in explosive atmospheres. 3.2. APPLICATION This pump was selected for a given set of pumping conditions and operating conditions in explosive atmospheres when the order was placed. will responsible for any damage caused if the information provided by the buyer is incomplete or incorrect (type of liquid, viscosity, RPM, classification of the potentially explosive zone, gas generated by the potentially explosive...
  • Page 7: Installation

    C Db CE ATEX mark inscribed on the manufacturer’s plate. If the equipment mark does not correspond to the order, INOXPA should be immediately informed of the situation. The temperature class and the maximum surface temperature depend on the temperature of the product to be pumped and the ambient temperature.
  • Page 8: Pipes

    The motors used must be EC marked in accordance with Directive ATEX 2014/34/EU and with the instructions of the manufacturer and the applicable national and local regulations. When pumping inflammable or explosive liquids, a proper connection must be used. Connect the parts of the assembly with the earth connections in order to reduce the risk of static electricity.
  • Page 9: Cooled Mechanical Seal

    Follow the motor manufacturer’s indications at all times. Protection against motor overload, suitable for the motor’s nominal power must also be installed. If necessary, install a separate fan, bearing in mind the environment where it will operate (potentially explosive atmosphere). 4.5.1.
  • Page 10 The end user must ensure that there is a constant flow to the pump by using a flow detector, flowmeter, or any other device in the pump intake, in order to prevent any increase in the surface temperature. Another option is to fit a temperature probe in the mechanical seal. 4.6.2.
  • Page 11: Starting Up

    5. Starting up Before starting up, those responsible must be duly informed about the pump and the safety instructions. This Annex, along with the instructions manual, will be available to staff at all times. In order to carry out any type of work in potentially explosive atmospheres, it is necessary to adopt special safety measures such as permits to work.
  • Page 12: Maintenance

    6. Maintenance 6.1. GENERAL INFORMATION The maintenance work of any equipment intended for use in potentially explosive atmospheres can only be carried out with the appropriate permit to work, as specified by ATEX 2014/34/UE. Maintenance jobs can only be done by qualified personnel. Use the proper clothing. Ensure that staff read the entire instructions manual and this Annex and, in particular, indicate those chapters that refer to the job to be done.
  • Page 13: Spare Parts

    INOXPA disclaims any liability for accidents or damage caused by failure to observe the instructions of the manual and of this Annex. 6.5.1. Preparations As well as the instructions given in the manual, the possibility of the presence of an explosive atmosphere must also be considered.
  • Page 14: Assembly / Disassembly Pump Casing

    6.5.5. Electrical safety In addition to the safety instructions given in the manual, the indications given by the motor manufacturer must be followed at all times in order to open the motor safely or lock it in. In addition to the instructions included in the manual, you must: Always observe the indications of the manufacturer of the motor and the mechanical seal if this has a temperature probe.
  • Page 15: Technical Specifications

    7. Technical Specifications Please to see 4.1.1. point to the maximum temperature values. Materials Parts in contact with the product AISI 316L (1.4404) Other Steel parts AISI 304L (1.4306) Gaskets in contact with the product EPDM (standard) FPM (other materials available upon request) Other gaskets Exterior surface finish Matt...
  • Page 16 b. Simple mechanical seal + thermosensor, balanced. The instructions of the mechanical seal manufacturer, and in particular those concerning the temperature probe, must be followed at all times. (C) 2022/11 7. Technical Specifications...
  • Page 17 NOTAS 7. Technical Specifications (C) 2022/11...
  • Page 18 INOXPA COLOMBIA SAS BOGOTÁ S.T.A. PORTUGUESA LDA Pbx 57-1-7427577 ALGERIZ inoxpa.colombia@inoxpa.com Tel. +351 256472722 comercial.pt@inoxpa.com In addition to our branches, INOXPA has a network of independent distributors in over 50 countries worldwide. For further information, visit our website www.inoxpa.com...