Installation The surface which you want to install the combustion fire must be as level as possible; Dimensions: To access to the control valve and tank (A) will be necessary to ensure a distance between the fireplace and potential obstacles on lateral sides superior to 300...
Page 6
Flammable materials Do not place flammable materials near the fireplace, within 1m; Racks or shelves should be distant: From fireplaces: 500 mm; From combustion fire lines: 1000 mm; Materials: stone/metal/ceramics A - 100 mm; Other non-flammable materials A - 250 mm;...
Page 7
Installation Procedures Very Important: We recommend extreme caution when unpacking your fireplace. The decorative rim is seated in the wall fastening plate, but it is loosened. In the installation placement, using the Hex Key (A), level the combustion fire- line using the bolts as described in the image below.
Page 8
Be sure that the steel plate (B), in between the elements of the Valve and the fire line is levelled out. Adjust the steel platform using the bolts if necessary (C). Then, proceed fitting the support basis with the screw holes pointed at (D). WARNING: Regarding the product, any disassembling or modification, not considered in this Manual, is strictly forbidden.
Page 9
Before each use, verify if there is some colour shifting inside the Leak Detector powder (G). If there is any difference in color, it means there was a leakage. If so, do NOT ignite the fireplace and contact a skilled technician. Any leak Leakage...