Warranty Information
Refer to your local Georg Fischer Sales office for the most
current warranty statement.
All warranty and non-warranty repairs being returned must
include a fully completed Service Form and goods must be
returned to your local GF Sales office or distributor.
Product returned without a Service Form may not be
warranty replaced or repaired.
Signet products with limited shelf-life (e.g. pH, ORP, chlorine
electrodes, calibration solutions; e.g. pH buffers, turbidity
standards or other solutions) are warranted out of box but not
warranted against any damage, due to process or application
failures (e.g. high temperature, chemical poisoning, dry-out) or
mishandling (e.g. broken glass, damaged membrane, freezing
and/or extreme temperatures).
Product Registration
Thank you for purchasing the Signet line of Georg Fischer
measurement products.
If you would like to register your product(s), you can now
register online in one of the following ways:
• Visit our website www.gfsignet.com.
Under Service and Support click on
Product Registration Form
• If this is a pdf manual (digital copy),
Operating Pressure/Temperature Graph
(psi)
(bar)
150
10.3
140
9.7
130
9.0
120
8.3
110
7.6
100
6.9
90
6.2
80
5.5
70
4.8
60
4.1
50
3.4
40
2.8
30
2.1
20
1.4
10
0.7
0
°C
-20
0
°F
-4
32
2
Signet 2580 FlowtraMag Meter
click here
DN25 (1 in.),
DN50 (2 in.)
DN100
@ 3.5 bar
(4 in.)
(51 psi)
@ 2.27 bar
(33 psi)
20
40
60
80
100
68
104
140
176
212
Chemical Compatibility
Georg Fischer Signet products are manufactured in a variety of
wetted materials to suit various liquids and chemicals.
All plastic materials including typical piping types (PVC) are more
or less permeable to contained media, such as water or volatile
substances, including some acids. This effect is not related to
porosity, but purely a matter of gas diffusion through the plastic.
If the plastic material is compatible with the medium according
to the application guidelines, the permeation will not damage
the plastic itself. However, if the plastic encloses other sensitive
components, as is the case with GF Signet FlowtraMag meter,
these may be affected or damaged by the media diffusing
through the plastic body.
Unit is factory shipped configured to measure water.
Safety Information
1. Depressurize and vent system prior to installation or removal.
2. Confirm chemical compatibility before use.
3. DO NOT exceed maximum temperature or pressure specs.
4. ALWAYS wear safety goggles or face shield during
installation and/or service.
5. DO NOT alter product construction.
6. If this equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired
7. This device is not approved for use or installation in
hazardous locations.
Caution / Warning / Danger
Indicates a potential hazard. Failure to follow all warnings
may lead to equipment damage, injury, or death
Electrocution Danger
Alerts user to risk of potential of injury or death via
electrocution.
Electrostatic Discharge (ESD)
Alerts user to risk of potential damage to product by ESD..
Personal Protective Equipment (PPE)
Always utilize the most appropriate PPE during
installation and service of Signet products.
Pressurized System Warning
Sensor may be under pressure, take caution to vent
system prior to installation or removal. Failure to do so
may result in equipment damage and/or serious injury.
Hand Tighten Only
Overtightening may permanently damage product threads
Hand tighten only!
and lead to failure. (union nut only)
Do Not Use Tools
Use of tool(s) may damage product beyond repair and
potentially void product warranty. (union nut only)
Note / Technical Notes
Highlights additional information or detailed procedure.
Need help?
Do you have a question about the Signet 2580 FlowtraMag and is the answer not in the manual?