Pioneer PDP-5050SX Service Manual page 98

Plasma display system
Hide thumbs Also See for PDP-5050SX:
Table of Contents

Advertisement

1
A
5
MSP Adjustment
Equipment : SG, Oscilloscope
Condition : Input RF level 60dBµV
5kHz STEREO 100% Lch Only
B
START
Select
ANT A
175.25 MHz
AIR
07
1
C
D
E
F
98
1
2
9
VR7503
(AV BOARD Assy)
PDP-5050SX
2
3
Adjust
Turn the wave pattern into a minimum.
minimum
Oscilloscope
CH1
CH2
(X)
(Y)
(AV BOARD Assy)
3
4
TP7503
4