5
3
Audio Level Adjustment
Equipment : SG, Digital mutimeter / Tester
Condition : Input RF level 60dBµV
1kHz MONO 100%
START
Select
ANT B
55.25 MHz
AIR
02
1
9
4
MSP Adjustment
Equipment : SG, Oscilloscope
Condition : Input RF level 60dBµV
300Hz STEREO 100% Lch Only
START
Select
ANT A
67.25 MHz
AIR
04
1
9
5
6
VR7504
(AV BOARD Assy)
VR7506
(AV BOARD Assy)
PDP-5050SX
6
7
Adjust TP7504 to 110mVrms
Digital multimeter
/ Tester
TP7504
(AV BOARD Assy)
Adjust
Turn the wave pattern into a minimum.
minimum
Oscilloscope
CH1
CH2
(X)
(Y)
TP7503
(AV BOARD Assy)
7
8
A
B
C
D
E
F
97