Service Tasks; Leak Test; Calibrating The Oil Scales (Only Vas 6381B) - Waeco AirCon Service Center Operating Manual

Air conditioning service unit
Table of Contents

Advertisement

VAS 6380B / VAS 6381B
9

Service tasks

9.1

Leak test

Check the AirCon Service Center once a year for leaks in accordance with
the applicable legal requirements. Use an electronic leak detector for this
purpose.
9.2
Calibrating the oil scales
(only VAS 6381B)
I
NOTE
In order for the oil quantities and the UV additive to be measured
correctly, the zero point of the scales must be checked regularly and
reset if necessary.
Resetting is necessary:
 If the quantity in a container deviates by more than 10 ml from the
target value
 If the AirCon Service Center has been shaken, for example during
transport on bumpy roads
 Every four to six weeks
1. In the basic menu, use the cursor keys  or  to select
"Other selections":
2. Press ENTER to confirm.
3. Use the cursor keys  or  to select "Reset Scales.":
✓ You are then prompted to remove the containers from the scales:
S h o r t s e l e c t i o n
F r e e s e l e c t i o n
O t h e r s e l e c t i o n s
E N T E R - O K S T O P - E X I T
I n t . v e s s e l f i l l i n g
F l u s h i n g
R e s e t S c a l e s .
S e r v i c e .
R e m o v e t h e 3 O i l / U V
g l a s s e s f r o m s c a l e s .
E N T E R - O K S T O P - E X I T