Editing Default Values - Waeco AirCon Service Center Operating Manual

Air conditioning service unit
Table of Contents

Advertisement

Initial startup
7.6

Editing default values

The AirCon Service Center has preset values for the most important
service tasks. The default values appear automatically when you select
the respective menu.
You can alter the following default values if necessary:
Parameter
Pressure increase Test time
Vacuum time min.
Leak Test
PAG Oil
UV Tracer
Filling Qt. g.
Print recovery value ?
1. In the basic menu, use the cursor keys  or  to select
"Other selections":
2. Press ENTER to confirm.
3. Use the cursor key  to select "Service.".
4. Press ENTER to confirm.
5. Enter the password "7388".
6. Use the keypad and the cursor keys to enter the information.
7. Press ENTER to confirm.
8. Press STOP to go to standby menu.
18
min.
min.
ml. (Extra amount)
ml.
S h o r t s e l e c t i o n
F r e e s e l e c t i o n
O t h e r s e l e c t i o n s
E N T E R - O K S T O P - E X I T
VAS 6380B / VAS 6381B
Default value
1
20
4
0
7
500
Yes