Filter Maintenance - Waeco AirCon Service Center Operating Manual

Air conditioning service unit
Table of Contents

Advertisement

Service tasks
11. Replace the O-rings (E).
12. Insert the new dryer and tighten the screw to max. 15°Nm.
9.4

Filter maintenance

I
NOTE
After finishing the service tasks, you must delete the respective service
messages (counter reset). To do this, switch to "Other selections" –
"Service." and enter the code "7782". Use the cursor keys  or  to
select the required entry and press ENTER to confirm. Follow the
display instructions, and press and hold the ENTER button for
3 seconds. Switch back to the previous selection using STOP.
When the filter is changed, the counter "R134a from system" must be
reset.
After changing the filter, perform a leak test (see chapter "Leak test" on
page 41).
"R134a from system" indicates how many grams of refrigerant have
been extracted from air conditioning systems using the menu item
"Short selection" or "Free selection" since the last reset (see date).
"R134a from tank" indicates how many grams of refrigerant were added
to the unit using the menu item "Int.vessel filling" since the last reset
(see date).
44
E
R 1 3 4 a f r o m s y s t e m
0 7 . 0 3 . 2 0 2 0
g .
S T O P - E X I T
R 1 3 4 a f r o m t a n k
0 7 . 0 3 . 2 0 2 0
g .
S T O P - E X I T
VAS 6380B / VAS 6381B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vas 6380bVas 6381b

Table of Contents