VAS 6380B / VAS 6381B
"Service completed:" displays the amount of service work performed
using the air conditioning service unit since the last reset (see date).
9.7

Meter readings

I
NOTE
The unit saves various meter readings. To access the total values –
consecutively, since the unit was produced – enter the menu
"Other selections" – "Service." and enter the code "7783". Use the
cursor keys  or  to select the desired entry.
These meter readings cannot be reset. To access the meter readings
which can be reset, enter the code "7782" under "Service.". Also see
chapter "Changing the vacuum pump oil" on page 46 or chapter
"Changing the dryer filter" on page 43.
"R134a from system" indicates how many grams of refrigerant have
been extracted from air conditioning systems using the menu item
"Short selection" or "Free selection" since the production of the
device (see date).
"R134a from tank" indicates how many grams of refrigerant were added
to the unit using the menu item "Int.vessel filling".
"R134a to system" indicates how many grams of refrigerant have been
filled into the air conditioning systems using the menu item
"Short selection" or "Free selection".
S e r v i c e c o m p l e t e d :
0 7 . 0 3 . 2 0 2 0
T o t a l
S T O P - E X I T
R 1 3 4 a f r o m s y s t e m
T o t a l
g .
S T O P - E X I T
R 1 3 4 a f r o m t a n k
T o t a l
g .
S T O P - E X I T
R 1 3 4 a t o s y s t e m
T o t a l
g .
S T O P - E X I T