Risks arising from installation and using the product condition of the locations and structures where the have been taken into consideration; these include: product E124 will be installed, prior to commissioning - Risks for the installation/maintenance technician the machine. These activities include the analysis of all...
SPENT BATTERY HAZARD Risk to the environment and health posed by batteries at the end of their lives due to WIRE STRIPPERS fluid escaping. EXPLOSION HAZARD Risk of explosion due to gas pro- duced by lead batteries building up inside the container (OPTIONAL). E124 532365 - Rev.A...
The required level of workplace lighting must be equal to at least 200 lux. Operate CE marked machinery and equipment in compli- E124 532365 - Rev.A...
3 E124 FAAC S.p.A. 1Y 11 03 19 identification code - It is prohibited to use the E124 in the presence of Made in Ireland faults which could compromise safety. update index date of construction...
BASIC and ADVANCED. In addition, remote programming from Simply Connect The E124 can control one or two 24 V " brushed mo- provides a larger number of options, including upload- tors, each having a maximum power of 70 W.
This is man- datory in the case of hold-to-run controls. The hold-to-run controls in the dead-man mode of operation, must comply with standard EN 60947-5-1. 2 E124 532365 - Rev.A...
Prepare the cable routing holes PREPARE THE CABLE ROUTING HOLES ( 4 ) Open the cable routing holes to a diameter suitable for the diameter if the conduits. Install suit- able cable glands. Ø16/20/25 (open to a suitable diameter) 4 E124 532365 - Rev.A...
INSTALL THE COVER (6) Insert the hinges for opening towards the left or right. Reinstall the cover OPENING TO THE RIGHT enclosure cover OPENING TO THE LEFT cover enclosure 6 5 E124 532365 - Rev.A...
CONNECTED. 1. (7) Disconnect the POWER connector and remove the cover of the board. 2. Remove the E124 board. 3. Remove the cover from the power supply. 4. (8) Place the selector switch to 120 V. 5. Put back the parts and insert the POWER connector.
OUT1 LAMP LOCK MOT1 MOT2 POWER Connector for switching power supply Connector (3 pin) for XF FAAC radio module BATTERY Connector for secondary power supply RADIO Connec tor (5 pin) for RP/DECODER FAAC/MiniDec boards 2EASY Removable terminal board for BUS 2easy...
NO type inputs (normally open) Devices with a NO contact must be connected to NO inputs: the com- mand is activated when the contact closes. Multiple NO contacts on same input must be connected in parallel. E124 532365 - Rev.A...
- further 8 s of pre-flashing). ELECTRIC LOCK (LOCK/ OUT1, OUT2) Gatecoder 2 E124 controls an electric lock to block the leaf in the closed position. Gatecoder 1 Connect the FAAC electric lock to the LOCK terminal board.
5-pin quick insertion connector. Insert it as shown in the figure. If a FAAC RP receiver is used, it is recommended to install the appropriate external antenna in order to obtain a sufficient range (see the device instructions).
- the display reverts to the automation status view. (SETUP required). If the SETUP has already been carried out , appears on the display and then the automation status (e.g. For LED and display signals see § Diagnostics. E124 532365 - Rev.A...
TYPE OF AUTOMATION Select the type of actuator installed (board loads the relative default configuration). The DEFAULT settings for the type of automation are indicated in the corresponding column (e.g. no FAAC actuator S418 column for S418). 412, 413, 415, 770, 390, 770N...
Page 19
. (point flashing) SLEEP S TAT I O N A RY T H E N CLOSING OPENS PRE-FLASHING and then FAIL- SAFE in progress CLOSES S TAT I O N A RY T H E N CLOSES EMERGENCY OPEN E124 532365 - Rev.A...
The pre-flashing time is fixed: 3 s. disabled when opening for any movement when the pause time elapses when closing CLOSING PHOTOCELLS Specifies the operation of the closing photocells. reopen when the photocells disengage reopen immediately E124 532365 - Rev.A...
Page 21
TIMER programming (from Simply Connect, not modifiable from the board). TIMING OUT2 Displayed if . Sets the duration of output OUT2, if a timed function is programmed. … Adjustment step: 1 min if , 1 s if E124 532365 - Rev.A...
Page 22
S TAT I O N A RY T H E N CLOSING ing) OPENS PRE-FLASHING and then FAIL- SAFE in progress CLOSES S TAT I O N A RY T H E N CLOSES OPENING in EMERGENCY E124 532365 - Rev.A...
SETUP has been completed. The board exits from programming mode and the display shows the automation status - closed. The phases are carried out automatically in sequence. * phase NOT carried out in the case of a single leaf automation. E124 532365 - Rev.A...
- The fourth consecutive obstacle, which is detected indicated by current regulations. in the same direction and position, is defined as the new mechanical stop of the leaf (when the obstacle is removed, the original length of travel is restored automatically). E124 532365 - Rev.A...
Refer to the actuator instructions for any additional tests that may be required. 6.7 CLOSE THE ENCLOSURE Close the enclosure using the screws on the cover. 10 E124 532365 - Rev.A...
Do not use the BUS 2easy line for emergency stop commands. 1 2 3 4 5 1 2 3 4 5 BUS 2easy control devices require E124 firmware version 0 0 0 0 0 Open A_1 0 0 0 0 1 Open A_1 Open B_1 FW 3.2 or later.
- note: BUS 2easy registration is also carried out via the SETUP. 2EASY BUS 2easy BUS 2easy BUS 2easy Do not exceed the maximum load of 500 mA. The overall length of the BUS 2easy cables must not exceed 100 m. 13 E124 532365 - Rev.A...
2. Press and hold down button P1 and check the LED: it becomes steady. 3. Without releasing the button, position the front of radio control to be added so that it is in contact with 18 E124 532365 - Rev.A...
To add additional radio controls, repeat the procedure from step 1. OPEN B COMMAND Proceed as for OPEN A, using button P2 on the radio control at steps 2 and 3 and checking LED R2 on the board. E124 532365 - Rev.A...
- after 5 s LED (R2 and R1) both start to flash quickly (deletion in progress) - after 5 s both the LEDs come on steadily (deletion complete) 2. Release the button, both LEDs switch off after ap- proximately 10 s. E124 532365 - Rev.A...
(SETUP and/or modifications to DL14 operating parameters). CLOCK BATTERY Simply Connect requires E124 firmware version FW PRGRM 4.0 or later. 8.8. When programming is taking place via Simply Connect, programming via the board is inhibited.
Use rechargeable lead batteries that can supply: Volt- age 20…28 V " , Current 16 A max. To install, use the BATTERY SUPPORT KIT (see FAAC cata- logue - includes the connection cables). 1. Remove the cover and set up the enclosure: To prevent the risk of explosion due to the build up of gas generated by lead batteries, drill a ∅...
not running ALARM Errors, Warnings error in progress warning in progress no warnings condition with the board powered, the gate at the halfway position and no connected devices active. 2 3 E124 532365 - Rev.A...
(OUT1, OUT2) (see advanced program- ming, functions Closing photocells Encoder 2 Photocells for OPEN A Closing sensitive edge E.g.: 1 or more OPEN A control devices and closing photocells are registered: OPEN A BUS 2easy Closing photocells 24 E124 532365 - Rev.A...
E124. Restore the previous settings or carry out Board thermal pro- Thermal overload protection active. the SETUP procedure. tection Wait for the E124 to cool down. SETUP incorrect or Perform SETUP. Check for overloads. missing Encoder 2 fault...
Battery discharged The charge level of the emergency bat- Control/Accessory The FW of the E124 or one if its ac- tery is too low for the movements to be board update in cessories is being updated via carried out. progress: it is not Simply Connect.
Check that the encoders operate correctly when an obstacle The table lists the operations that should be per- is detected. formed on a regular basis on the E124 board in order Control devices Check that the installed control devices and to keep the automation working reliably and safely;...
- After approximately 10 s, appears on the display and LEDS R1 and R2 light up. 3. Release the buttons. - LEDs R1 and R2 switch off. - After approximately 10 s, flashes on the display (SETUP required). E124 532365 - Rev.A...
■ OBSTACLE DETECTION BY BOARD OR ENCODER closing, causes the gate to reverse and then closes it If an obstacle is detected during opening or closing, immediately. the leaf reverses (ANTI-CRUSHING), then the automa- tion stops. E124 532365 - Rev.A...
Page 42
Maintained OPEN opens the automation. OPEN if the automation is closed, causes it to Maintained CLOSE closes the automation. open. The automation closes automatically after the If the photocells are triggered, movement is stopped. pause time has elapsed. E124 532365 - Rev.A...