  • Page 2 CON I DIP SWITCH DS1(DS3-DS4) L’OPERATORE EQUIPMENT WITH THE DS1(DS3-DS4) DIP COLLEGATO ALL’APPARECCHIATURA E024S. SWITCHES. PER TUTTI GLI ALTRI SETTAGGI FARE RIFERIMENTO FOR ALL OTHER SETTINGS, REFER TO THE E024S AL MANUALE ISTRUZIONI E024S. INSTRUCTION MANUAL. ATTENTION ACHTUNG AVANT D'EFFECTUER LE SETUP , SÉLECTIONNER VOR DER DURCHFÜHRUNG EINES SETUPS MUSS...
  • Page 3: Table Of Contents

    REMOTE MEMORY STORAGE OF RC/LC RADIO CONTROLS ..................12 RADIO CONTROLS DELETION PROCEDURE ..................12 BATTERY KIT OF E024S (OPTIONAL)....................12 9.1 BATTERY KIT OF E024S ON 391 (OPTIONAL) ..................13 AUTOMATED SYSTEM TEST .......................13 BUS ENCODER WIRING ........................13 FUNCTION LOGICS .........................15 CE DECLARATION OF CONFORMITY Manufacturer: FAAC S.p.A.
  • Page 4: Box Layout

    ELECTRICAL BOX E024S The cover hinges can be moved upward to allow opening the BOX LAYOUT box housing (Fig. C); they can also be removed and re-posi- tioned in order to enable the cover to open to the right or left. THE BOX CONTAINS THE E024S CONTROL UNIT AND THE DEVICES TO POWER IT. IT MUST THEREFORE BE HANDLED WITH CARE DURING ALL INSTALLATION STAGES, TO AVOID DAMAGING ITS COMPONENTS. The dimensions of the box are shown in Fig.A: Fig. C When you have secured the box in the selected position, cover the securing holes (ref.a Fig.B) and the screws with the supplied...
  • Page 5: Warnings E024S

    LAYOUT AND CONNECTIONS E024S 230 V~ 50HZ 115 V~ 60Hz Motors connection (TOTAL OPENING) 2x2.5 mm ² / AVG 12 for motor (minimum) (PARTIAL OPENING) (Max. length 20 m) Fig. 1A THE POWER SUPPLY IS RELATED TO THE E024S PURCHASED VERSION. E024S 732642 - Rev. F...
  • Page 6: Warnings E024S Fitted On 391

    LAYOUT AND CONNECTIONS E024S FITTED ON 391 Motors connection (PARTIAL OPENING) 2x2.5 mm ² / AVG 12 for motor (minimum) (TOTAL OPENING) (Max. length 20 m) 230 V~ 50HZ 115 V~ 60Hz Fig. 1B THE POWER SUPPLY IS RELATED TO THE E024S PURCHASED VERSION. E024S 732642 - Rev. F...
  • Page 7: Technical Specifications

    90 seconds. * The power supply and the fuse are related to the purchased version. The self-resetting fuse F1 stops the power supply to the ANTI-CRUSHING FUNCTION accessories by opening a circuit if a current over 500 mA is The electronic anti-crushing function is obtained by controlling detected. It automatically resets after 5 seconds. the current consumption or the encoder of the motors DESCRIPTION OF COMPONENTS connected to the E024S unit. POWER SUPPLY connector If the gate detects an obstacle during the opening or closing movement, the anti-crushing function activates and reverses SERVICE LIGHT command terminal-board the sense of direction of the operator, thus increasing the safety FLASHING LAMP terminal-board degree of the automated system. ELECTRIC LOCK terminal-board COMMANDS terminal-board...
  • Page 8: Start-Up

    Then the leaves start again to move automatically one at a Before performing the Setup, select the op- time from the closed position. erator connected to the E024S unit with the 1. Open impulse --->leaf 1 decelerated opening and start of DS1(DS3-DS4) DIP switches. the search for leaf 1 opening limit stop TIME LEARNING – SETUP - if the limit stop is detected, it is set as stop point for leaf 1 and leaf 2 starts to open.
  • Page 9: Programming The Logic

    Dead man 7 times Flashing 7 times * With menus 6 and 7, keep the LOGIC push- button pressed until reaching the time to be set. The time can be set between 0 and 4.25 minutes. E024S 732642 - Rev. F...
  • Page 10: Return To Default Settings

    Make sure that there are not two or more pairs of photocells with the same address. OPENING and CLOSING If no BUS accessory is used, leave the BUS con- nector free (J10 - fig. 1). OPEN PULSE E024S 732642 - Rev. F...
  • Page 11: Memory Storage Of Bus Accessories

    MEMORY STORAGE OF BUS ACCESSORIES delete the existing one (see paragraph on deletion), It is possible to add BUS accessories to the system at any time and repeat the memory-storage procedure. by simply saving them on the board, in the following manner: 1. Install and program the accessories using the required address (see paragraph 7.1) E024S on 391 2. Cut power to the board. 3. Connect the two accessories cables to the red terminal-board J10 (any polarity will do). 4. Power up the board, taking care to first connect the main power supply (transformer output) and then any batteries and wait for the BUS LED to light on.
  • Page 12: Memory Storage Of Rc/Lc Radio Controls

    Make sure that the automated system is free of any obstacle created by persons or things. BATTERY KIT OF E024S (OPTIONAL) 8.3 MEMORY STORAGE OF RC/LC RADIO CONTROLS The buffer battery kit was built for insertion inside the control board support.
  • Page 13: Battery Kit Of E024S On 391 (Optional)

    9.1 BATTERY KIT OF E024S ON 391 (OPTIONAL) The battery kit enables you to activate the automated system even in the event of a mains power fault. The batteries are housed in a specific compartment inside the operator (see 3.9 x 16 sequence in fig. 6). To install, refer to the specific instructions. The batteries start operating when mains voltage fails. AUTOMATED SYSTEM TEST When you have finished programming, check if the system is operating correctly. In particular, check if the safety devices Fig. 6 are operating correctly. BUS ENCODER WIRING E024S is used to control bus encoders. Any encoders connected to the red bus terminal are recognised during bus device acquisition (chapter 7.2). The use of this type of encoder offers precise and constant information on leaf position, guaranteeing reverse movement in case of obstacles. The encoder is compulsory on hydraulic operators (S450H, S700H, S800H, S800H ENC) and optional on electromechanical operators. Leaf 1 opens as first and closes as second...
  • Page 14 DL 2 Leaf 1 encoder Leaf 2 encoder DL 3 Pulse reading during leaf movement If necessary, swap the 2 connecting wires to obtain the correct coupling of the encoder with the leaf as indicated in the following figure. Fig. 8 E024S 732642 - Rev. F...
  • Page 15: Function Logics

    OPEN IN PAUSE pause time of stops operation no effect pause time pause time (1) released leaf (CLOSE disabled) (CLOSE disabled) reopens leaves reopens leaves reverses at opening stops and opens at CLOSING stops operation no effect immediately immediately release (saves CLOSE) no effect no effect no effect no effect BLOCKED closes leaves closes leaves (OPEN/CLOSE (OPEN/CLOSE disa- (OPEN disabled) (CLOSE disabled) disabled) bled) (1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening E024S 732642 - Rev. F...
  • Page 16 (CLOSE disabled) (OPEN/CLOSE disabled) disabled) stops and opens at release CLOSING stops operation stops operation stops operation no effect reverses at opening (OPEN stops - saves CLOSE) restarts moving in restarts moving in no effect no effect opposite direction. opposite direction. no effect no effect BLOCKED (OPEN/CLOSE (OPEN stops - Always closes after Always closes after (OPEN disabled) (CLOSE disabled) disabled) saves CLOSE) STOP STOP (1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening E024S 732642 - Rev. F...
  • Page 17 (OPEN/CLOSE no effect (OPEN/CLOSE disa- OPEN (CLOSE disabled) disabled) bled) CLOSING opens the leaves no effect stops operation no effect stops operation stops operation no effect no effect no effect no effect BLOCKED opens the leaves closes leaves (OPEN/CLOSE (OPEN/CLOSE disa- (OPEN disabled) (CLOSE disabled) disabled) bled) E024S 732642 - Rev. F...