The A line's concluding information as follow:
1.Standby state: SPH is in standby state. No error in this state, but for other reasons, make it in a
wait state.
2.Normal state: SPH is normal working state.
3.Bypass state: Grid power the UPS load state while SPH inverter can't power UPS load.
4.Checking state: SPH is in self-check state, if there is no error or warning, SPH will go to normal
state or standby state. Otherwise it will go to fault state.
5.Programming state: SPH is in updating firmware state.
6.Fault state: SPH has fault information, it will be in stopped operational protection state.
The B line's information as follow:
In normal, it will turn on page automatically, when pushing the button "UP", the
order of the paging information as follow:
WorkMode
Input&Output Para
WorkMode
(Lead acid)Vb:xx.xV
(Lithium)Vb/Cb:xx.xV/xxx%
Battery information
WorkMode
Battery power
Pbat: (+/-)XXXX W
WorkMode
PV1/PV2 voltage
Vpv:xxxV/xxxV
WorkMode
PV1/PV2 input power
Ppv:xxxxW/xxxxW
WorkMode
Grid information
Grid:xxxV/xxHz
WorkMode
Output AC Power
Po:xxxxW/xxxxVA
WorkMode
UPS:xxxV/xxHz
UPS output voltage
WorkMode
UPS output power
UPS:xxxxW/xxxxVA
Power to grid or to user
To grid is -
To user is +
WorkMode
Pm: (+/-)XXXXW
Chart 6.5
43
WorkMode
PV1/PV2 today energy
Epv_d:xxxx.x KWh
WorkMode
PV1/PV2 total energy
Epv_a:xxxx.x KWh
WorkMode
BAT Charge_today
Ec_d:xxxx.x KWh
energy
WorkMode
BAT Charge_total
Ec_a:xxxx.x KWh
energy
WorkMode
BAT Discharge_today
Ed_d:xxxx.x KWh
energy
WorkMode
BAT Discharge_total
Ed_a:xxxx.x KWh
energy
WorkMode
AC output_Etoday
Eac_d:xxxx.x KWh
WorkMode
AC output_Etotal
Eac_a:xxxx.x KWh
WorkMode
System Time
20XX/XX/XX/ XX:XX
WorkMode
Serial number
SerNo:xxxxxxxxxx
WorkMode
Machine model
Model:xxxxxxxxxx
WorkMode
Firmware version
FW Version:xxxx
Note:
1."Down" control command (if pushing "up" button, command will go back)
2.Workmode depend on the situation. If SPH is normal state, it will show
"normal". If SPH is standby state, it will show as "standby" etc.
3.Some special definitions are explained, for example: Vb means the voltage of
battery. Cb means the capacity of lithium battery (only lithium battery show this
data). Pm means the monitor power of user.

6.4.4 Work mode set up

Keep pressing "enter "for 3S,you can enter set up surface,in the set up surface you
need hold button Enter or ESC 1S for selection,you can see the surface as showing
below.
Press "enter" key more than
3 seconds into setup mode
WorkMode
Configuration
Press "down" key
to the next item
If you choose CEI and used SPH inverter in Italy, SPH inverter have Auto Test function.
How to use the Auto test function. Please see the annex.
1.Under the Basic Para ,you can see the setup options below after pressing Enter for
1S:
Press "enter" key more
than 1 seconds to make sure
WorkMode
WorkMode
Basic Parameter
Language
Press "down" key
to the next item
WorkMode
System time
WorkMode
Only display when
battery type is lead-acid
Lead-acid CV
Only display when
WorkMode
battery type is lead-acid
Lead-acid LV
WorkMode
Only display when
battery type is lead-acid
Lead-acid CC
WorkMode
Basic Parameter
Press "enter" key more
than 1 seconds to make sure
WorkMode
BackUp
WorkMode
Priority
WorkMode
MODE Change
WorkMode
ExportLimit
WorkMode
Default Set
WorkMode
Auto Test
Chart 6.6
Press "enter" key more
than 1 seconds to make sure
WorkMode
English
Italian
German
WorkMode
xxD/xxM/xxxxY
WorkMode
Range from 55 to 60V,
and the accuracy is 0.1V
58.0 V
WorkMode
Range from 42 to 50V,
and the accuracy is 0.1V
48V
WorkMode
Range from 0 to 75A, and
the accuracy is 0.1A
75 A
Chart 6.7
44