SMC Networks PB Series Manual

SMC Networks PB Series Manual

Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids

Advertisement

Quick Links

Process Pump
(Diaphragm Pump)
Compact, large capacity diaphragm pump, suitable
Compact, large capacity diaphragm pump, suitable
Compact, large capacity diaphragm pump, suitable
for transferring and collecting a wide range of fluids
for transferring and collecting a wide range of fluids
for transferring and collecting a wide range of fluids
25
25
25
Smaller, lighter,
Smaller, lighter,
Smaller, lighter,
* PB1013A/Air-operated type without foot
1.5
1.5
Long
Long
Long
service life
service life
service life
(Comparison with current PB series)
0.11
0. 0.11
kg
kg
kg
Weight
Weight
Weight
∗ PB1013A/Air-operated type without foot
37
37
37
mm
mm
mm
Space saving (Air operated)
pathological inspection device
Low particle generation due to the diaphragm
structure
Flammable fluids can be used.
Self-priming makes priming unnecessary.
Sucks the liquid even if the pump is dry.
Assembled in a clean room. Double packaged
Easy to adjust the flow rate by the frequency
of ON/OFF of the solenoid valve.
PB
Series
%
%
reduction in volume
reduction in volume
reduction in volume
(Comparison with current PB series)
8
8
times
times
times
Discharge
Discharge
Discharge
∗ PB1013A and PB1313A are available up to 1000 ml/min.
Actual
size
(PB1013A)
Reagents transfer in a
Body wetted
parts
(Air operated)
(PB1313A)
Built-in solenoid valve
Built-in solenoid valve
Built-in solenoid valve
2000
2000
2000
min ∗
to
to to
ml/min
m ml/mi
52
52
52
mm
mm
mm
Application Examples
Application Examples
Application Examples
Car washing
Printing
machine
machine
Water/
Ink/solutions
detergents
supply
supply
Machine
tool
Oil supply
Polypropylene
Stainless steel 316
PB1011A
PB1011A
PB1011A
PB1013A
PB1013A
PB1013A
Air operated
Air operated
Air operated
New
New
RoHS
Semiconductor/
Analyser
LCD equipment
for medical and
DI water/solutions
biochemistry
supply, Waste fluid
Reagents
collection
supply
Cleaning
Devices related
device
to solar cell/
DI water/
secondary battery
hydro-carbonic
Electrolyte/
cleaning liquid
DI water supply
supply
Body: New PFA
Wetted
materials
Diaphragm: PTFE
PB1313A
PB1313A
PB1313A
Air operated
Air operated
Air operated
CAT.EUS100-90A-UK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PB Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks PB Series

  • Page 1 ∗ ∗ Smaller, lighter, Smaller, lighter, Smaller, lighter, reduction in volume reduction in volume reduction in volume (Comparison with current PB series) * PB1013A/Air-operated type without foot 2000 2000 2000 Long Long Long min ∗...
  • Page 2 <AIR SUP> with better resistance. Air supply port RoHS Fluid passage area comparison <FLUID IN> times (Comparison with current PB series) Suction port Mounting Variations Note) Mounting orientation: <FLUID OUT> port on top only Front mounting Rear mounting Side mounting ∗...
  • Page 3 Series PB1313A PB1313A Series Series Air Operated/Wetted Materials: Fluoropolymer Air Operated/Wetted Materials: Fluoropolymer Compact pump for DI water/chemicals Compact pump for DI water/chemicals For transferring and collecting DI water/chemicals ∗ Wetted New PFA Body ∗ Refer to page 14 for applicable fluids. materials: PTFE Diaphragm...
  • Page 4 Process Pump (Diaphragm Pump) Body Wetted Parts: Polypropylene/Stainless Steel Built-in Solenoid Valve/Air Operated (External switching type) PB1000A Series RoHS How to Order PB101 Built-in Solenoid Valve PB1011A Actuation Made to Order Symbol Actuation (For details, refer to page 5.) Built-in solenoid valve —...
  • Page 5 PB1000A Process Pump Series Built-in Solenoid Valve/Air Operated Flow-rate Characteristics Built-in Solenoid Valve (PB1011A) Selection from Flow-rate Characteristic Graph Cycle (1 Hz) Cycle (5 Hz) Cycle (7 Hz) Required specification example SUP = 0.7 MPa Find the pilot air pressure for a discharge rate of 600 ml/min and a SUP = 0.7 MPa SUP = 0.7 MPa...
  • Page 6 PB1000A Series Working Principle: Built-in Solenoid Valve/Air Operated Discharge port When air is supplied with the built-in solenoid valve turned ON (energized), air <FLUID OUT> enters the driving chamber and the diaphragm moves to the left. Due to this movement, the fluid in the pump chamber passes through the upper check valve and is discharged to the discharge port <FLUID OUT>.
  • Page 7 PB1000A Process Pump Series Built-in Solenoid Valve/Air Operated Dimensions Built-in Solenoid Valve AIR SUP PB1011A Rc, NPT, G 1/8 FLUID IN Rc, NPT, G 1/8 AIR EXH M5 x 0.8 Thread depth 8 2 x ø4.5 Manual Mounting hole override pin Foot (Option) 2 x M4 x 0.7...
  • Page 8 PB1000A Series Made to Order Please contact SMC for detailed dimensions, specifications and lead times. Liquid contact seals SF7000 (Perfluoropolyether rubber) PB101 A Actuation Made to Order Symbol Actuation Liquid contact seals SF7000 Air operated Option Thread type Symbol Option —...
  • Page 9 Process Pump (Diaphragm Pump) Wetted Materials: Fluoropolymer Air Operated (External switching type) PB1313A Series RoHS How to Order Port size Main fluid Connection size Symbol connection size in the air side Female thread Actuation Rc1/8 Symbol Actuation NPT1/8 Air operated G1/8 Tube extension Diaphragm material...
  • Page 10 PB1313A Series How to Order Fittings for Products with Nut (PB1313AS) Fittings compatible for the process pump with nut/PB1313AS. Product without nut (insert bushing), 1 piece nut removed, which is not necessary in cases when using the products with nut. E 21 SN LQ1 fittings Fitting type...
  • Page 11 PB1313A Process Pump Series Air Operated Flow-rate Characteristics: Air Operated (PB1313A) Cycle (1 Hz) Cycle (5 Hz) SUP = 0.5 MPa SUP = 0.5 MPa SUP = 0.4 MPa SUP = 0.4 MPa SUP = 0.3 MPa SUP = 0.3 MPa SUP = 0.2 MPa SUP = 0.2 MPa 1000...
  • Page 12: Piping Diagram

    PB1313A Series Working Principle: Air Operated When air is supplied with the external 3-port solenoid valve turned ON Discharge port (energized), air enters the driving chamber and the diaphragm moves to the left. <FLUID OUT> Due to this movement, the fluid in the pump chamber passes through the upper check valve and is discharged to the discharge port <FLUID OUT>.
  • Page 13 PB1313A Process Pump Series Air Operated Dimensions Air Operated PB1313A FLUID IN Rc, NPT, G 1/8 With LQ1 fitting With LQ3 fitting (ø6.35) (1.2) AIR SUP Rc, NPT, G 1/8 With nut (LQ1/LQ3 fittings) 1/4" tube extension FLUID OUT Rc, NPT, G 1/8 Caution 1.
  • Page 14: Related Products

    Series Related Products 1 Specifications 3 Port Solenoid Valve SYJ314/514 /714 SYJ314 SYJ514 SYJ714 Model Piping Base mounted Valve construction Rubber seal Type of actuation N.C. Maximum operating pressure 0.7 MPa Minimum operating pressure 0.15 MPa C[dm /(s·bar)] 0.41 2 (P 0.18 0.41 0.32...
  • Page 15 Series Related Products Model Specifications Filter Regulator + Mist Separator AC20D AC30D AC40D AC40D-06 AC20D AC30D AC40D AC40D-06 Model Model Air Combination AC20D/30D/40D Proof pressure 1.5 MPa Filter Series AW20 AW30 AW40 AW40-06 regulator 1.0 MPa Max. operating pressure 0.05 MPa Min.
  • Page 16 Series Related Products 2 High Purity Chemical Valves Refer to “Best Pneumatics No. 7” Series for further details. Air operated Air operated Manually operated Air operated Air operated/ Integral fitting type Threaded type Integral fitting type/ Compact type Manually operated Series Series Threaded type...
  • Page 17 4. The applicability may vary depending on impurities. Take note also to determine the model. of impurities. • The material of the diaphragm of PB series is PTFE. PTFE is sui- 5. Examples of transfer liquids are shown below. Since the applicabil- table for non-permeating liquids.
  • Page 18: Air Supply

    • Flammable fluid cannot be used with the process pump with 2. The port thread material of PB series is resin. Use a built-in solenoid valve (PB1011A). Do not use in an environ- fitting with a resin thread for piping the fitting.
  • Page 19: Maintenance

    Series Specific Product Precautions 2 Be sure to read this before handling. Refer to back cover for Safety Instructions. Read the “Operation Manual” carefully before use to understand the outline of the product and issues relating to safety. The Operation Manual can be downloaded from the SMC website: http://www.smcworld.com/ Operating Environment Maintenance...
  • Page 20: Safety Instructions

    These safety instructions are intended to prevent hazardous situations and/or Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for ∗1) safety and must be followed in addition to International Standards (ISO/IEC) and other safety regulations.

This manual is also suitable for:

Pb1011aPb1013aPb1313a

Table of Contents