Summary of Contents for SMC Networks PA3000 Series
Page 1
NS100-39B ® Process Pump Series PA3000/5000/PAX1000 Series PB1000 Air or Solenoid Operated Self Priming Long Life Double or Single Pump Types SHOP ONLINE at www.airlinehyd.com 800-999-7378...
Page 2
Compact, high capacity transfer and recovery of Long life, 2 to 5 times that of conventional pumps Incorporates a new diaphragm material. Enlarged bore size and shortened stroke extend life. (compared to series PA2000) High abrasion resistance and low particle generation No sliding parts in wetted areas.
Page 3
diaphragm pump for a wide variety of fluids Process Pump Variations Series PA /Double acting pump Material Discharge flow Series Action Model rate l/min (SCFM) Body Diaphragm AIR SUP FLUID OUT 1 to 20 (0.035 to 0.7) Automatically PTFE ADC12 PA3000 operated type AIR EXH...
Series PA3000/5000 Process Pump Automatically Operated Type (Internal Switching Type) How to Order PA3000 PA 3 Body size Option Body only 3/8 standard ∗ With silencer 1/2 standard ∗ For AIR EXH: AN200-02 Liquid contact Connection port size body material 3/8 (10A): PA3 ADC12 (aluminum) 1/2 (15A): PA5...
Page 5
Series PA3000/5000 Process Pump Automatically Operated Type Performance Curves/Automatically Operated Type PA5000 PA3000 Flow rate characteristics Flow rate characteristics Discharge rate /min Discharge rate /min 1m = 3.28ft /min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Page 6
Series PA3000/5000 Process Pump Automatically Operated Type Operating Principle/Automatically Operated Type Air exhaust port Switching valve Air supply port Pilot valve A Pilot valve B Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Shaft Suction port (FLUID IN) Drive Drive...
Page 7
Series PA3000/5000 Process Pump Automatically Operated Type Piping and Operation/Automatically Operated Type Piping diagram Pilot air supply port AIR SUP Discharge port FLUID OUT Silencer Option Suction port FLUID IN Pilot air exhaust port AIR EXH Caution Maintain the proper tightening torque for fittings and mounting bolts, etc. Looseness can cause problems such as fluid and air leaks, while over tightening can cause damage to threads and parts, etc.
Page 8
Series PA3000/5000 Process Pump Automatically Operated Type Dimensions/Automatically Operated Type (mm) 1in = 25.4mm PA3000 4-ø7 Reset button (185) FLUID OUT AIR SUP (pilot air supply port) FLUID PROCESS PUMP FLUID AIR EXH (pilot air exhaust port) FLUID IN PA5000 4-ø9 FLUID OUT AIR SUP...
Page 9
Series PA3000/5000 Process Pump Air Operated Type (External Switching Type) How to Order PA3000 PA 3 Body size Connection port size 3/8 standard 3/8 (10A): PA3 1/2 standard 1/2 (15A): PA5 3/4 (20A): PA5 Liquid contact body material Thread type ADC12 (aluminum) PA5000 SCS14 (stainless steel)
Page 10
Series PA3000/5000 Process Pump Air Operated Type 1l/min = 0.035SCFM 1m = 3.28ft Performance Curves/Air Operated Type 1MPa = 145psi PA3 13 PA5 13 Flow rate characteristics Flow rate characteristics Cycle 7Hz Cycle 7Hz Cycle 5Hz Cycle 5Hz Cycle 3Hz Cycle 3Hz (no change when SUP=0.2, 0.3MPa) (no change when SUP=0.2MPa)
Page 11
Series PA3000/5000 Process Pump Air Operated Type Operating Principle/Air Operated Type Air supply port (AIR SUP) 5 port solenoid valve Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Shaft Suction port (FLUID IN) Drive Drive Diaphragm A Diaphragm B chamber B chamber A...
Page 12
Series PA3000/5000 Process Pump Air Operated Type Piping and Operation/Air Operated Type Piping diagram Pilot air supply port: Discharge AIR SUP port FLUID OUT Suction port Pilot air supply port: FLUID IN AIR SUP Solenoid valve Caution Maintain the proper tightening torque for fittings and mounting bolts, etc. Looseness can cause problems such as fluid and air leaks, while over tightening can cause damage to threads and parts, etc.
Page 13
Series PA3000/5000 Process Pump Air Operated Type Dimensions/Air Operated Type (mm) 1in = 25.4mm PA3000 4-ø7 FLUID OUT AIR SUP (P1) FLUID PROCESS PUMP FLUID AIR SUP (P2) FLUID IN PA5000 4-ø9 FLUID OUT AIR SUP (P1) 1/2, 3/4 RESET FLUID PROCESS PUMP...
Page 14
Series PAX1000 Process Pump Automatically Operated Type with Built-in Pulsation Attenuator (Internal Switching Type) How to Order PAX1 Option Body material Body only ∗ ADC12 (aluminum) With silencer ∗ For AIR EXH: AN200-02 SCS14 (stainless steel) Connection port size 1/4 (8A) Diaphragm material 3/8 (10A) PTFE (fluororesin)
Page 15
Series PAX1000 Process Pump Automatically Operated Type Built-in Pulsation Attenuator Performance Curves/Automatically Operated Type with Built-in Pulsation Attenuator Selection from flow rate characteristic graph PAX1000 Flow rate characteristics Required specification example: Find the pilot air pressure and pilot air consumption for a discharge rate of 6 /min and a total lifting range of 25m.
Page 16
Series PAX1000 Process Pump Automatically Operated Type Built-in Pulsation Attenuator Operating Principle/Automatically Operated Type with Built-in Pulsation Attenuator Air exhaust port Air supply port Change lever (AIR EXH) (AIR SUP) Pulsation attenuator intake valve Pulsation attenuator Switching valve exhaust valve Pilot valve B Pilot valve A Pump chamber A...
Page 17
Series PAX1000 Process Pump Automatically Operated Type Built-in Pulsation Attenuator Piping/Automatically Operated Type with Built-in Pulsation Attenuator Piping diagram Reset button Reset button Pilot air supply port AIR SUP Discharge port FLUID OUT Suction port Silencer FLUID IN Pilot air exhaust port AIR EXH Caution Maintain the proper tightening torque for fittings and mounting bolts, etc.
Series PAX1000 Process Pump Automatically Operated Type Built-in Pulsation Attenuator Dimensions (mm) 1in = 25.4mm 4-M8 (M6 hexagon socket head screw can be inserted) Mounting hole detail Reset button RESET (175) AIR SUP (pilot air supply port) FLUID IN PROCESS PUMP 1/4, 3/8 FLUID OUT 1/4, 3/8...
Page 19
Series PB1000 Process Pump Built-in Solenoid Valve Type/Air operated Type (External Switching Type) How to Order 1 0 1 Body size Option/Part no. 1/8 standard Pump only With foot (bolts included) Body material KT-PB1-3 Polypropylene ∗ With silencer AN120-M5 ∗ For AIR EXH Diaphragm material Air operated type is not PTFE (fluororesin)
Page 21
Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Operating Principle/Built-in Solenoid Valve Type/Air Operated Type Discharge port (FLUID OUT) Diaphragm Drive chamber Return spring Built-in solenoid valve (3 port valve) The PB1013 air operated type does not have a built-in solenoid valve. (AIR SUP) Suction port Air supply port...
Page 22
Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Piping and Operation/Built-in Solenoid Valve Type/Air Operated Type Piping Bottom view Foot (optional) Top view Manual override pin ∗ The PB1013 air operated type has a plug in the air exhaust port EXH. Caution Be sure that the discharge side OUT is on top when the pump AF) together with a mist separator (Series AM).
Page 23
Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Dimensions/Built-in Solenoid Valve Type/Air Operated Type (mm) 1in = 25.4mm PB1000 FLUID OUT Mount with this surface (OUT port side) on top UP SIDE PROCESS Mounting PUMP position MODEL PB1011 SUPPLY PRESS AIR 0.2~0.7MPa VOLTAGE...
Page 24
Series PA3000/5000 Related Products Related Products (Refer to the individual product catalogs for further details.) Specifications 5 port solenoid valve Model VQZ1420 VQZ1440 VQZ2420 VQZ2440 VQZ14 0/24 0 Piping Body ported Base mounted (exhaust center) Valve construction Metal seal Type of actuation 3 position exhaust center Maximum operating pressure 0.7MPa (101psi) (high pressure type 1.0MPa) (145psi)
Series PA3000/5000 Related Products Related Products (Refer to the individual product catalogs for further details.) Standard specifications/Single style (standard dew point –20°C (–4°F)) Membrane Dyer Standard dew point –20°C Series Model IDG5 IDG10 IDG20 IDG30 IDG50 Compressed air Fluid Macromolecular membrane dryers Inlet air pressure that act like filters 0.3 to 0.85 (43 to 123)
Page 26
Series PA3000/5000 Process Pump Automatically Operated Type Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO4413 Note 1) , ISO4414...
Page 27
Series PA3000/5000 Process Pump Automatically Operated Type Process Pump Common Precautions 1 Be sure to read before handling Refer to the main catalog sections for detailed precautions on each series Precautions on Design Warning Warning 1. Confirm the fluid to be used. 9.
Page 28
Series PA3000/5000 Process Pump Automatically Operated Type Process Pump Common Precautions 2 Be sure to read before handling Refer to the main catalog sections for detailed precautions on each series Selection Piping Warning Caution 1. Preparation before piping 1. Confirm the specifications. Give careful consideration to operating conditions such as the Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other...
Page 29
Series PA3000/5000 Process Pump Automatically Operated Type Process Pump Common Precautions 3 Be sure to read before handling Refer to the main catalog sections for detailed precautions on each series Operating Environment Maintenance Warning Warning 1. Do not use in the following environments, as 1.
Page 30
Series PA3000/5000 Process Pump Automatically Operated Type Process Pump Common Precautions 4 Be sure to read before handling Refer to the main catalog sections for detailed precautions on each series Maintenance Lubrication Caution Caution 6. Service life and replacement of consumable 1.
Series PA3000/5000 Process Pump Automatically Operated Type Process Pump Common Precautions 5 Be sure to read before handling Refer to the main catalog sections for detailed precautions on each series Fluid Compatibility Caution 3. These products are not suitable for use in medical applications 1.
Page 32
® World Wide Support... North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics Inc. (Milwaukee) SMC Pneumatics Inc. (Atlanta) SMC Pneumatics Inc. (Cleveland) SMC Pneumatics Inc. (Richmond) 1440 Lakes Parkway, Suite 600 2305 East Aurora Rd., Unit A-3 16850 W.
Need help?
Do you have a question about the PA3000 Series and is the answer not in the manual?
Questions and answers