Technical Data
A
0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure or 7.5 MPa, 75 bar (1050 psi) hydraulic oil pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure or 4.2 MPa, 42 bar (600 psi) hydraulic oil pressure
Test Fluid: No. 10 Weight Oil
30
Dura-Flo 900 Pumps with NXT Model 2200 Air Motors, Pump Ratio 21:1
psi (MPa, bar)
9
2000 (14.0, 140)
1800 (12.6, 126)
A
1600 (11.2, 112)
1400 (9.8, 98)
1200 (8.4, 84)
B
1000 (7.0, 70)
800 (5.6, 56)
600 (4.2, 42)
C
400 (2.8, 28)
200 (1.4, 14)
0
0.5
(1.9)
(3.8)
Dura-Flo 900 Pumps with NXT Model 3400 Air Motors, Pump Ratio 30:1
psi (MPa, bar)
9
3500 (24.1, 241)
3000 (21.0, 210)
A
2500 (17.2, 172)
2000 (14.0, 140)
B
1500 (10.3, 103)
1000 (7.0, 70)
C
500 (3.5, 35)
0
0.5
(1.9)
Key
Cycles per Minute
18
27
36
45
54
1.0
1.5
2.0
2.5
3.0
(5.7)
(7.6)
(9.5)
(11.4)
Fluid Flow in gpm (lpm)
Cycles per Minute
18
27
36
45
1.0
1.5
2.0
2.5
(3.8)
(5.7)
(7.6)
(9.5)
(11.4)
Fluid Flow in gpm (lpm)
63
72
90
A
80
70
60
B
50
40
C
30
20
10
3.5
4.0
(13.3)
(15.2)
54
63
72
140
A
120
100
B
80
60
C
40
20
3.0
3.5
4.0
(13.3)
(15.2)
311828F