8. Mounting

CAUTION
Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Safety switches and actuators must not be used as an end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about mounting the safety
switch and the actuator.
Ì
From the assured release distance S
Ì
When mounting several safety switches, observe the stipulated minimum distance to avoid mutual
interference.
Ì
If the actuator is installed flush, the operating distances change as a function of the installation
depth and the guard material.
Note the following points:
Ì
Actuator and safety switch must be easily accessible for inspection and replacement.
Ì
Actuator and safety switch must be fitted so that
- the front faces are at the minimum operating distance 0.8 x S
the area of possible side lobes, a minimum distance is to be maintained in case of a side approach direction. See
chapter 12. Technical data, section Typical actuating range for the related actuator.
- when the guard is open up to the distance S
- the actuator is positively mounted on the guard, e.g. by using the safety screws included.
- they cannot be removed or tampered with using simple means.
Ì
Pay attention to the maximum tightening torque for the read head or safety switch and actuator fastenings of 1 Nm.
2112663-08-02/20 (Translation of the original operating instructions)
.
Flush mounting
Actuator
Operating
distance
(assured release distance), a hazard is excluded.
ar
Non-Contact Safety Switch CES-AP-C01-...
, the safety outputs are safely shut down.
ar
min . 40 mm
Surface mounting
Actuator
or closer when the guard is closed. To avoid entering
ao
Operating Instructions
Operating
distance
EN
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ces-ap-c01 series

Table of Contents