Technical Data Of Actuator Ces-A-Bba; Dimension Drawing; Operating Distances - EUCHNER CES-AP Series Operating Instructions Manual

Non-contact safety switch unicode/multicode
Table of Contents

Advertisement

12.2.

Technical data of actuator CES-A-BBA

Parameter
Housing material
Dimensions
Weight
Ambient temperature
Degree of protection
Installation orientation
Power supply

12.2.1. Dimension drawing

42
CES-A-B 071840
32 ±0,1
NOTICE
2 safety screws M4x14 included

12.2.2. Operating distances

Actuating range for center offset m = 0
Parameter
Operating distance
Assured operating distance s
ao
Switching hysteresis
Assured release distance s
ar
1) The values apply to surface mounting of the actuator on metal.
2112663-08-02/20 (Translation of the original operating instructions)
min.
-25
12
4,6
Active face
1)
min.
-
15
1
-
Non-Contact Safety Switch CES-AP-C01-...
Value
typ.
Plastic (PPS)
42 x 25 x 12
0.02
-
IP65/IP67/IP69/IP69K
Active face opposite read head
Inductive via read head
Active face
Value
typ.
18
-
3
-
Operating Instructions
Unit
max.
mm
kg
+70
°C
Unit
max.
-
-
mm
-
45
21
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ces-ap-c01 series

Table of Contents