EUCHNER CES-AP Series Operating Instructions Manual

EUCHNER CES-AP Series Operating Instructions Manual

Non-contact safety switch unicode/multicode
Table of Contents

Advertisement

Quick Links

Operating Instructions
Non-Contact Safety Switch
EN
CES-AP-C01-... (Unicode/Multicode)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CES-AP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for EUCHNER CES-AP Series

  • Page 1 Operating Instructions Non-Contact Safety Switch CES-AP-C01-… (Unicode/Multicode)
  • Page 2: Table Of Contents

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… Contents About this document ..................... 4 1.1. Scope ............................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................5 Description of the safety function ................6 Exclusion of liability and warranty ................. 6 General safety precautions ...................
  • Page 3 Operating Instructions Non-Contact Safety Switch CES-AP-C01-… Technical data ....................19 12.1. Technical data of safety switch CES-AP-C01-… ................19 12.1.1. Typical system times ......................20 12.1.2. Dimension drawing of safety switch CES-AP-C01-… ............20 12.2. Technical data of actuator CES-A-BBA .....................21 12.2.1. Dimension drawing ......................21 12.2.2.
  • Page 4: About This Document

    Important! Always read all documents to gain a complete overview of safe installation, setup and use of the device. The documents can be downloaded from www.euchner.com. For this purpose enter the doc. no. in the search box. (Translation of the original operating instructions) 2112663-08-02/20...
  • Page 5: Correct Use

    Ì EN 60204-1 The safety switch is only allowed to be operated in conjunction with the intended EUCHNER CES actuators and the related connection components from EUCHNER. On the use of different actuators or other connection components, EUCHNER provides no warranty for safe function.
  • Page 6: Description Of The Safety Function

    Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. For this reason you should archive a printed copy of the operating instructions. You can download the operating instructions from www.euchner.com. (Translation of the original operating instructions) 2112663-08-02/20...
  • Page 7: Function

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 6. Function The safety switch monitors the position of movable guards. The safety outputs are switched on/off when the actuator is moved to/removed from the actuating range. The system consists of the following components: coded actuator (transponder) and switch. Whether the device learns the complete actuator code (unicode) or not (multicode) depends on the respective version.
  • Page 8: Changing The Approach Direction

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 7. Changing the approach direction NOTICE Risk of damage to equipment as a result of trapped cables or seals. Ì Make sure that the cables or seals are not trapped or torn off when the approach direction is changed.
  • Page 9: Mounting

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 8. Mounting CAUTION Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Ì Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by- passing an interlocking device. NOTICE Risk of damage to equipment and malfunctions as a result of incorrect installation.
  • Page 10: Electrical Connection

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 9. Electrical connection WARNING In the event of a fault, loss of the safety function due to incorrect connection. Ì To ensure safety, both safety outputs must always be evaluated. Ì Monitoring outputs must not be used as safety outputs. Ì...
  • Page 11: Notes About

    Use connection components and connecting cables from EUCHNER. Ì On the use of other connection components, the requirements in the following table apply. EUCHNER provides no warranty for safe function in case of failure to comply with these require- ments. Ì...
  • Page 12: Connector Assignment Of Safety Switch Ces-Ap-C01

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 9.5. Connector assignment of safety switch CES-AP-C01 Plug connector 8-pin 5-pin View of connection side on the safety switch 8-pin 5-pin 5-pin; pin 5 not used n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c.
  • Page 13: Connection

    The user is responsible for safe integration into the overall system. Detailed application examples can be found at www.euchner.com. Simply enter the order number of your switch in the search box. You will find all available connection examples for the device in Downloads.
  • Page 14 Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 24 V DC Monitoring Safety Output Outputs Connected load Figure 3: Connection example CES-AP-… with reset button (Translation of the original operating instructions) 2112663-08-02/20...
  • Page 15: Notes On Operation With Safe Control Systems

    19. A detailed example of connecting and setting the parameters of the control system is available for many devices at www.euchner.com, in the area Downloads/Applications/CES. The features of the respective device are dealt with there in greater detail. 9.8. Devices for direct connection to IP65 field modules The version CES-AP-...-SB-...
  • Page 16: Setup

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 10. Setup 10.1. LED displays Color State Meaning illumi- Normal operation nated STATE green - Teach-in operation or power-up flashing - Actuator in limit range (from V0.1.2) (refer to chapter 11. System status table on page 18 for further signal functions) illumi- - Internal electronics fault nated...
  • Page 17: Functional Check

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 10.3. Functional check WARNING Danger of fatal injury as a result of faults in installation and functional check. Ì Before carrying out the functional check, make sure that there are no persons in the danger zone. Ì...
  • Page 18: System Status Table

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 11. System status table LED indicator Output Operating mode State closed Normal operation, door closed Inverted closed flash Normal operation, door closed, actuator in the limit range Re-adjust door ¨ burst Normal operation open Normal operation, door open open Normal operation, door open;...
  • Page 19: Technical Data

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 12.1. Technical data of safety switch CES-AP-C01-… Parameter Value Unit min. typ. max. Housing material PBT plastic Dimensions Acc.
  • Page 20: Typical System Times

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.1.1. Typical system times Refer to the technical data for the exact values. Ready delay: After switch-on, the device carries out a self-test. The system is ready for operation only after this time. Turn-on time of safety outputs: The max. reaction time t is the time from the moment when the actuator is in the actu- ating range to the moment when the safety outputs switch on.
  • Page 21: Technical Data Of Actuator Ces-A-Bba

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.2. Technical data of actuator CES-A-BBA Parameter Value Unit min. typ. max. Housing material Plastic (PPS) Dimensions 42 x 25 x 12 Weight 0.02 Ambient temperature °C Degree of protection IP65/IP67/IP69/IP69K Installation orientation Active face opposite read head Power supply Inductive via read head 12.2.1.
  • Page 22: Typical Actuating Range

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.2.3. Typical actuating range (only in combination with actuator CES-A-BBA) - 3 0 - 3 0 For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.
  • Page 23: Technical Data Of Actuator Ces-A-Bda-18

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.3. Technical data of actuator CES-A-BDA-18 Parameter Value Unit min. typ. max. Housing material - Sleeve PBT-GF30, thermoplastic plastic - Active face PEEK 450, thermoplastic plastic Fixing screw tightening torque Dimensions ∅ 18 x 9 Weight 0.003 Ambient temperature...
  • Page 24: Typical Actuating Range

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.3.3. Typical actuating range (only in combination with actuator CES-A-BDA-18 on surface mounting) - 3 0 - 2 5 - 3 0 For a side approach direction for the actuator and read head, a minimum distance of s = 8 mm must be maintained so that the actuating range of the side lobes is not entered.
  • Page 25: Technical Data Of Actuator Ces-A-Bpa

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.4. Technical data of actuator CES-A-BPA Parameter Value Unit min. typ. max. Housing material Dimensions 40 x 40 x 10 Weight 0.025 Ambient temperature - 25 + 70 °C Degree of protection IP65/IP67/IP69/IP69K Installation orientation Active face opposite read head Power supply Inductive via read head...
  • Page 26: Typical Actuating Range

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.4.3. Typical actuating range (only in combination with actuator CES-A-BPA on surface mounting) - 4 5 - 4 5 For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
  • Page 27: Technical Data Of Actuator Ces-A-Brn

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.5. Technical data of actuator CES-A-BRN Parameter Value Unit min. typ. max. Housing material Dimensions 80 x 40 x 15 Weight 0.06 Ambient temperature - 25 + 70 °C Degree of protection IP67 Installation orientation Active face opposite read head Power supply Inductive via read head...
  • Page 28: Typical Actuating Range

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 12.5.3. Typical actuating range (only in combination with actuator CES-A-BRN on surface mounting on metal) - 1 0 - 1 5 - 2 0 - 2 5 - 3 0 - 3 5 - 4 0 - 4 5 - 5 0 - 5 5...
  • Page 29: Ordering Information And Accessories

    13. Ordering information and accessories Tip! Suitable accessories, e.g. cables or assembly material, can be found at www.euchner.com. To order, enter the order number of your item in the search box and open the item view. Accessories that can be combined with the item are listed in Accessories.
  • Page 30: Declaration Of Conformity

    Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 16. Declaration of conformity (Translation of the original operating instructions) 2112663-08-02/20...
  • Page 31 Operating Instructions Non-Contact Safety Switch CES-AP-C01-… 2112663-08-02/20 (Translation of the original operating instructions)
  • Page 32 Edition: 2112663-08-02/20 Title: Operating Instructions Non-Contact Safety Switch CES-AP-C01-… (Translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 02/2020 Subject to technical modifications; no responsibility is accept- ed for the accuracy of this information.