3/ Installation - AQUALUX DUO Electrolyse + pH 105448 Installation And Care Instruction

Salt chlorinator + ph 40 m3, 80 m3
Table of Contents

Advertisement

Available languages

Available languages

3/ INSTALLATION

Before proceeding with installation of the device, it is imperative to check the following points :
 Ensure that any hydraulic equipment is in good working order and is correctly sized. In particular, check
the flow of the filtration pump, the capacity of the filter and the diameter of the waterworks.
 The maximum pressure of the water in the cell must not exceed 3 bars.
 The device's treatment capacity should be adapted to the volume of water to be treated and in the
climate of the place of installation. In case of warm climate, a device designed to treat a volume of 30 m
in moderate climate must be limited to a family swimming pool of 20m
3
volume of 50 m
designed to treat a volume of 70 m
3
50m
.
Be careful with natural water sources (drilling waters) !
Preferably use water from the public water supply. Avoid using any water from natural sources (rain, run off water,
reservoirs, and wells) under risk of early deterioration of chlorination cell.
 The installation area should be dry, correctly closed, but properly ventilated (maximal ambient
temperature of use: 35°C), protected the whole of equipment from rain, splashes, water spray, and UV
radiation.
 Select a location for the can of the pH corrector product that is far enough away from any electrical
equipment or any other chemicals
 Failure to comply with this instruction will lead to anormal oxidation of the metallic parts which could
result in complete breakdown of the device.
 The assembly of the devices must be performed strictly in compliance with the following layout diagram:
DUO AQUALUX – PAPI004070 – FR – EN – DE – Rev.03.16
in moderate climate must be limited to a family swimming pool of 40m
3
in moderate climate must be limited to a family swimming pool of
2
1
3
, a device designed to treat a
3
, a device
T assembly of the cell
3
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Duo electrolyse + ph 105449

Table of Contents