Chlorine Production Regulation - AQUALUX DUO Electrolyse + pH 105448 Installation And Care Instruction

Salt chlorinator + ph 40 m3, 80 m3
Table of Contents

Advertisement

Available languages

Available languages

 Activate the pool cover mode (Code "Co" in the control menu, see § 4.2) and confirm with
 By default, state is OF, select ON and confirm by
display returns to the control panel (display of the production %).
 When the pool cover will be closed, the device will shows :
5

CHLORINE PRODUCTION REGULATION

The chlorine production of the device settles in production percentage, from 00 to 10 (100 %), using
putting on standby).
Check the rate of free chlorine production of the pool with your usual analysis kit. The free chlorine
must be around 1 ppm. If it is not the case, settles the device on the position 10 (100 %) and let run in
continuous work until obtaining a sufficient concentration (from few hours to few days).
 As soon as the free chlorine reaches 1 ppm, put the filtration on « AUTO » and calibrate the time filtration
according to the following board :
T(°C)
16
Time (h)
8
Calibrate the production % so as to maintain the free chlorine level in the pool between 0,5 and 1
particle by million. In the starting up, in first estimation, adjust with the following values :
Note : Every use of pool is different, it could be necessary several tests to determine the most adapted value to the
situation.
Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a pH
regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks and
damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other factors
may cause damage, in particular:
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable...)
- manual processing of supplements excessive or not adapted (choc processing...)
- the non-compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer's responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.
DUO AQUALUX – PAPI004070 – FR – EN – DE – Rev.03.16
18
20
22
9
10
11
3
40 m
Model
Pool volume
Setting
3
(
)
of %
m
3
40 m
10
3
35 m
09
3
30 m
08
3
25 m
06
3
20 m
05
Your device is now ready.
; the chosen state is registered and then the screen
V
Co
26
24
13
12
3
80 m
Model
Pool volume
Setting
3
(
)
of %
m
3
80 m
10
3
75 m
09
3
70 m
08
3
65 m
07
3
60 m
06
.
V
28
30
More
16
19
24/24
(0
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Duo electrolyse + ph 105449

Table of Contents