Winterizing; Cleaning Of The Cell - AQUALUX DUO Electrolyse + pH 105448 Installation And Care Instruction

Salt chlorinator + ph 40 m3, 80 m3
Table of Contents

Advertisement

Available languages

Available languages

6 /MAINTENANCE

WINTERIZING

1
Bellow a temperature of water of 15°c, the chemical conditions of the water pull a premature wear of the
chlorinator cell. It is compulsory to switch off its salt chlorinator (« wintering mode »).
 Stop the device by putting the production to 00 (0 %). It will set in stand-by mode after few seconds.
 If the cell is not fed by the controller box, it will not damage the chlorinator cell if you let it on the
tubing, it will not damage it. Make, then a classical chemical treatment without stabilizer.
 In any case water can have to be frozen in the cell.
 All damages linked to no respect of instructions entail the annulation of the guarantee.
 At the start up, the next year, switch on again the device by pressing on any touch. If the free
chlorination level is lower than 1 particle by million, make shock chlorination and follow the start up
advises (checking of the water parameters, the rate of salt, of the cell, of the regulation of the chlorine
production percentage).
 Remove the pH probe of the pipe. Keep it in his original protection filled with city water (or in a glass),
in a place where it will not freeze during winter.
 On the pipe, in probe place, use supplied plug.
 Rinse the flexible pipe of the peristaltic pump with clean water. Put a tin of water in the place of the
pH corrective agent tin and use the function "MA" of the pH control menu

CLEANING OF THE CELL

2
Self-cleaning avoid the limestone deposits in the cell. However, if the cell is nevertheless scaled, proceed to a
manual cleaning:
 Turn off filtration, remove the cell and check scale deposit presence on the electrodes.
 To remove the scale deposits on the cell, use a cleaner « special cell » or contact your local retailer :
 Rinse the cell and then reassemble it
 If necessary, recalibrate your inversion frequency in the reduction (see §5.3).
The lifespan of the cell is very closely linked to the respect for the instructions indicated in this user manual. We
recommended using exclusively cells of origin. The use of "compatible" cells can entail a reduction in the production
and reduce the life cycle of the device. A deterioration linked to the use of a compatible cell cancels the contractual
warranty by that fact.
DUO AQUALUX – PAPI004070 – FR – EN – DE – Rev.03.16
Connexions must be
Connexions must be
outside the water
outside the water
cleaning solution
cleaning solution
In line cell
In line cell
Titanium plates
Titanium plates
totally immerged
totally immerged
T cell
T cell
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Duo electrolyse + ph 105449

Table of Contents