DMPS3-4K-350-C and DMPS3-4K-250-C Series
3-Series® DigitalMedia™ Presentation Systems
Circuit Overloading: Consideration should be given to the
l
connection of the equipment to the supply circuit and the effect
that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this
concern.
Reliable Earthing: Reliable earthing of rack-mounted equipment
l
should be maintained. Particular attention should be given to supply
connections other than direct connections to the branch circuit
(for example, use of power strips).
To install the device into a rack:
1. Using a #2 Phillips screwdriver and the six included 6-32 x 5/16-inch
Phillips Undercut Head screws, attach the two included rack ears to
the device (three screws for each rack ear).
2. Mount the device into the rack using four rack mount screws (not
included).
Rack Ear Attachment
Placing onto a Flat Surface
Before placing the device onto a flat surface, attach the four included feet
to the corners on the underside of the device.

Connect the Device

Connect the device as required for the application.
NOTES:
The DM INPUT and DM OUTPUT ports are PoDM+ power sourcing
l
equipment (PSE) ports and are HDBaseT PoE+ compatible. The
CONTROL SUBNET port is a PoE PSE port. Enabling PoDM+,
HDBaseT PoE+, and PoE power sourcing requires connection of the
PoDM+ INPUT PWR port to an external Crestron power supply
(PW-5430DUS or DM-PSU-3X8-RPS, sold separately). Wiring that
connects to a PoDM+, HDBaseT PoE+, or PoE PSE is designed for
intrabuilding use only.
As an alternative to using the main LAN port for AirMedia or H.264
l
content input, the CONTENT LAN port can be used to provide a
secondary LAN connection that is dedicated to either AirMedia or
H.264 content input.
Electrical Connection:
"This product must be connected to an earthed mains socket-outlet."
Finland: "Laite on liitettävä suojamaadoituskoskettimilla
l
varustettuun pistorasiaan."
Norway: "Apparatet må tilkoples jordet stikkontakt."
l
Sweden: "Apparaten skall anslutas till jordat uttag."
l
Refer to the following illustrations for connection information.