Connecting External Controllers And Analog Devices; Remote Control From Amx Or Crestron ([Network] Connector); Controlling An Analog Device ([Fault Output] Connector) - Yamaha TX4n Reference Manual

Yamaha power amplifier reference manual
Hide thumbs Also See for TX4n:
Table of Contents

Advertisement

Connecting External Controllers and
Analog Devices

Remote control from AMX or Crestron ([NETWORK] connector)

You can connect an Ethernet-compatible controller such as AMX or Crestron to the amplifier's [NETWORK]
connector, and remotely control the amplifier.
When connecting a remote controller, you must specify the amplifier's Port No. The Port No. setting can be made
from the panel of the TXn amplifier or via Amp Editor. For details, refer to
manual.
• For details of the remote control communication protocol, please refer to the "TXn Remote Control Protocol Specification"
NOTE
provided on the website.
http://www.yamahaproaudio.com/

Controlling an analog device ([FAULT OUTPUT] connector)

You can connect a lamp etc. to the rear panel [FAULT OUTPUT] connector to
indicate that an abnormality has occurred.
The [FAULT OUTPUT] connector consists of NO (Normally Open), C (Common), and
NC (Normally Closed). The [FAULT OUTPUT] connector is a relay circuit, and oper-
ates as follows.
Normal state
NO
Open
NC
Closed
The relay contacts used in the [FAULT OUTPUT] connector are rated for a load of 1A, DC 30V. Do not apply a load that
exceeds this rating.
Use Amp Editor to make settings for the [FAULT OUTPUT] connector.
Euroblock plugs are used for the [FAULT OUTPUT] connector. Euroblock connection methods are described in
plug connection" (page 52)
in this manual.
• In Amp Editor's [Device Setup] menu ➝ [Alert Setup], you can set Type to Fault so that a fault can be indicated by a con-
NOTE
nected lamp, etc. For details on making settings, refer to the "Amp Editor owner's manual."
● Example : Using an LED to indicate normal/fault status of the TXn
Normal state
TXn
• The relay contacts are rated for a resistive load of 1A, DC 30V. Do not apply a load that exceeds this rating.
CAUTION
Abnormal state
Closed
Closed
Open
Open
Lit
NC
C
NO
Unlit
page 21
or to the Amp Editor owner's
Powered-off
Powered-off / Abnormal state
TXn
NC
C
NO
"Euroblock
Unlit
Lit
TX6n/5n/4n Reference Manual