Delayed Egress
ED4000, ED5000 Series Exit Device
Installation Instructions
15
Wiring Diagram - Single Door Exit Only
Operation:
Mechanical trim can be added for entry. Ingress by trim without touching device push bar rim will not
affect alarm if a door position switch is not being used. Refer to DPS wiring if necessary.
Connector
J2
(Device)
16
Wiring Diagram - Single Door With Remote Inputs & Monitoring Outputs
Operation:
Monitoring: Red LED indicates device is armed and secure. Activating device will sound alarm. (Figure 10)
Green LED will illuminate after 15 seconds. Device will release for exit (unsecure).
NOTE: If dry contacts are needed for signaling or monitoring, a 24VDC relay is recommended.
ALR NO/NC
BLU
EGND
ORG
*Connect EGND within
BPS Power Supply or
Local Building Ground
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2006, 2010, 2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
QC8
Wire
Transfer
Hinge
(-)
+24VDC
QC8
*Connect to EGND
Figure 10
18
(-)
Securitron
+24VDC
BPS
Po wer
Supply
*Connect to EGND
Figure 9
120 VAC
To NC
Fire Alarm
Contacts
FM209 10/20