Programming Guide

SCPI command syntax

The following conventions are used for SCPI command syntax for remote interface
programming.
– Square brackets ([]) indicate optional keywords or parameters.
– Braces ({}) enclose parameter choices within a command string.
– Angle brackets (<>) enclose parameters for which you must specify a value.
– A vertical bar (|) separates multiple parameters.

Commands relevant to the J7204/5/A/B

To set the attenuation level
The following command is used to set the attenuation level of the J7204/5/A/B.
Syntax
ROUTe:SEQuence:TRIGger <ATTEN_X_Y_Z>
Parameter
ATTEN_X_Y_Z
Keysight J7204/5/A/B Operating and Service Manual
a X = attenuator channel number
b Y = attenuator selection (each channel consists of one 11 dB and 110 dB
attenuator pair)
i
1 = 11 dB attenuator in 1 dB step
ii 2 = 110 dB attenuator in 10 dB step
c Z = attenuation value
i
0 = 0 dB attenuation
ii 80 = 8 dB attenuation
iii 100 = 100 dB attenuation