9

Power-On Procedures

1. Align Close Position Magnet with sensor.
2. Turn power on at the Unit On/Off Switch
located on the end cap.
3. Turn Breaker Switch to "Reset" (Breaker
Switch shown in step 8). Red LED in
breaker should be on and circuit board
LEDs should illuminate.
10
Control Set-Up
Inverter Control Board Adjustments:
Based on function adjustment desired, use
table below to determine which POT is to
be adjusted.
Required: Magnets must be adjusted for
specific application.
E
POT
Motor Torque at Hold Open
H/O TQ
Backcheck Position
P1
Sweep Closing Force (90° - 20°)
M/DLY
Motor Delay on Opening
H/O TM
Hold Open Time (5 - 30 Seconds)
OBSTR SENS
Obstruction Detection on Open
P2
Latch Force (20° - 0°)
11
Signage
Affix "Caution" Labels on both sides
of the door. Labels should be
centered across the width of the door
and 50" from the floor.
Copyright © 2013, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ADJUSTMENT TABLE
DESCRIPTION
Sensor
E
P2
OBSTR
SENS
H/O TM
SW501
PUSH PULL
K2
JMP503
K1
PB
COM
SNS
FUNCTION
11
COM
TB501
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
ELECTRIC SHOCK RISK!
CCW - Decrease
(Adjustments made in the shaded
area should be performed by
Authorized Factory Personnel.)
7
Close Position Magnet
Open Position
M/DLY
P1
MOTOR OUT
H/O TQ
NO
STATUS LEDS
115/230VAC IN
NC
WARNING
Center
50"
80-9356-0005-020 (01-14)
ASSA ABLOY
Magnet
W
V
U
L2
230Y
L1
L2
115Y

Advertisement

Table of Contents
loading

Table of Contents