Opening and Closing Adjustments
A. Turn potentiometers (shown below) to make any adjustments. The table below shows the times
required per ANSI/BHMA A156.19 (American National Standard for Power Assist and Low Energy
Power Operated Doors) for opening and closing based on the door width and weight.
Increase
Decrease
Hold Open Delay
(5-30 sec)
Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Opening Speed
Adjustment
Sweep Speed Adjustment
(Speed of door closing from
open to Latch Speed Range)
Page 11
Latch Speed Adjustment
(Speed of door closing
from Sweep/Latch
transition point to close)
Open Delay 1
(Delay before door opens
after an activation from
Input 1)
Open Delay 2
(Delay before door opens
after an activation from
Input 2)
Contact Factory for
assistance with
additional settings
Available adjustment for
Special Application
Requests
80-9363-0003-020 Rev 8 11/17