Parameters

Program parameters

Description
Program active
A program must be active to be
chosen and started.
Wash time (sec)
Length of the "wash phase".
If this setting is 0, the "wash
phase" and "pause before
rinse" is skipped.
Pause before rinse (sec)
Length of the pause between
"wash phase" and "rinse
phase" in seconds.
Rinse time (sec)
Length of "rinse phase".
Pause after rinse (sec)
Lenth of the pause after rinse
(in seconds).
Wash temperature
The wanted temperature in °C
for washing.
Min. wash temperature
The lowest tempearature in °C
a wash can be started at.
Rinse temperature
The wanted temperature in °C
for rinsing.
Detergent dosing calibration
High/Low wash pressure
Exhaustion during...
Exhaustion after rinse (sec)
Indicates number of seconds
the exhaustion must run after
the rinse phase.
Condensing after rinse (sec)
Indicates number of seconds
the condensator must run after
the rinse phase.
KEN DW 412
Subject to alterations
Possible
Adjustments from factory
adjustments
Prog. 1 Prog. 2 Prog. 3
Yes/no
Yes
0-999
60
0-999
15
0-999
12
0-999
15
1-99
57
1-99
49
1-99
80
A-B-C-D
A
Low
Low
High,
Low/High,
High/Low
None
Wash+
Wash+
Wash
Rinse
Rinse
Rinse
Wash+Rinse
0-999
300
0-999
0
Prog. 4
Yes
Yes
Yes
120
240
600
15
15
15
12
12
12
15
15
15
57
57
57
49
49
49
80
80
80
A
A
A
Low
Low
Low
Wash+
Wash+
Rinse
Rinse
300
300
300
0
0
0
User adjustments