Trouble shooting/error codes

Display/error #55 - #"200

#55 DRAIN FAULT
(only if drain pump is
installed)
#65 HOOD FAULT
Input has at a time during the wash/
rinse period been without signal.
#76 DEF. THERMOSENSOR
WASH TANK
Thermal-sensor in wash tank
short-circuited or disconnected.
#77 DEF. THERMOSENSOR
RINSE TANK
Thermal-sensor in rinse tank
short-circuited or disconnected.
#85 HOOD SECURITY ENABLED
#86 HOOD BLOCKED
#200 INT. SW FAULT
Defective control module.
KEN DW 412
Subject to alterations
Cause
1. Drain blocked.
2. Defective drain pump.
1. Poor wire connection/contactor
2. Reed contakt defect or wrongly
adjusted.
1. Error in connection between
thermal-sensor TS1 and input.
2. Defective thermal-sensor TS1.
1. Error in connection between
thermal-sensor TS2 and input.
2. Defective thermal-sensor TS2.
1. Some is preventing for automatic
closing of hood.
2. Error at microswitch for security.
3. Error at lift motor.
1. Some is preventing for automatic
closing of hood.
2. Error at microswitch for
security.
3. Error at lift motor.
1. Control module is broken.
NB! Remedying an error that requires the use of tools to remove the
machine cover plates may only be carried out by specially trained,
technical staff.
Remedial action
To be cleaned.
To be repaired.
To be repaired.
To be replaced or adjusted to make
sure that it does not break e.g. by an
untimely attempt to open the hood.
Wire to be repaired.
To be replaced.
Wire to be repaired.
To be replaced.
Checked.
Adjusted / replaced.
Repared / replaced.
Checked.
Adjusted / replaced.
Repared / replaced.
Call in a service technician.