9500
Remove the probe holder or probe cable from the probe input
>
To unlock, turn the probe input anti-clockwise. The arrow on the probe holder shows the open
padlock on the probe input.
>
Pull the probe holder from the input.
Insert the probe in the probe holder
>
Push the probe into the probe holder using a slight turn/push movement. The arrow on the
probe and on the probe holder must align.
-
When aligned correctly, all 6 lugs will lock into the respective groove on the probe.
>
Reinsert the probe holder or plug the probe into the cable and screw in place.
>
To lock the probe input in place, turn clockwise until it locks. The arrow on the probe holder
points at the locked padlock on the probe input
Connect the probe to the probe cable
>
Screw the probes together with the cable.
>
For better probe guidance, insert the probe into the probe holder of the gauge.
The gauge is now ready for use.
To remove a probe, follow the above steps in reverse order.
3.3 Check Basic Settings
Check and, if necessary, change the factory settings of your device. At a minimum, check the settings
for
>
the language
>
the unit
>
the date and time
>
the configuration of the
button and
>
the power save options
These settings can be found in the "System" menu.
The settings pertaining to the measurement job can be found in the menu "Jobs", "Limits" and "Cali-
bration".
16
16 / 48
3 Initial Operation
QNix 9500 EN_ES_FR_IT_NL_PL
4 Operation and Controls
3.4 Software Backup
The "QN9" is loaded on the device. This software is used to later manage the device and the record-
ed measurements on the PC. Back this software up to your PC.
NOTICE
Formatting will erase all data
Formatting the memory will also erase the software from the device.
You can download the software from www.q-nix.com/download.
4 Operation and Controls
4.1 About Operation
Please note the following instructions to ensure conclusive results:
>
Hold the device by the probe holder
>
Carefully place the device or the probe perpendicular on the surface
>
Ensure the probe makes good contact with the surface and avoid the probe shaking
>
Do not drag the probe across the coated surface
If the device does not register a measurement or no button is pushed within the amount of time set
under menu "System" > "Power save options", the display will first dim, then the device will switch
off.
To reduce unstable measurements, you can set a delay from when the probe is applied and meas-
urement starts. For the settings, go to menu "Settings" > "Probe" > "Measure"
4.2 Calibration
The gauge will need to be calibrated before first using it, after replacing the battery, for different
measurement jobs, or as necessary. Either use our reference plates or, ideally, a piece of uncoated
material being tested.
NOTICE
Push softkey to start calibration
On delivery, the
button is programmed to the function "Start calibration". You can start the
calibration directly from the measurement display. The calibration will then be executed with the
preset parameters.
NOTICE
Incorrect calibration
Calibrating with the incorrect reference plate can reduce accuracy.
NOTICE
Using reference plates
The included test films are not certified. Certified films are available from the address in chapter
Service and Repair [page. 35].
QNix 9500 EN_ES_FR_IT_NL_PL
9500
17 / 48
17

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QNix 9500 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Qnix 9500bQnix 9500p

Table of Contents